Fabrication, Characterization, and Hemocompatibility Investigation of Polysulfone Grafted With Polyethylene Glycol and Heparin Used in Membrane Oxygenators. Issue 11 (November 2016)
- Record Type:
- Journal Article
- Title:
- Fabrication, Characterization, and Hemocompatibility Investigation of Polysulfone Grafted With Polyethylene Glycol and Heparin Used in Membrane Oxygenators. Issue 11 (November 2016)
- Main Title:
- Fabrication, Characterization, and Hemocompatibility Investigation of Polysulfone Grafted With Polyethylene Glycol and Heparin Used in Membrane Oxygenators
- Authors:
- Zheng, Zhi
Wang, Weiping
Huang, Xin
Lv, Quan
Fan, Wenling
Yu, Wenkui
Li, Lei
Zhang, Zhibing - Abstract:
- Abstract: Polysulfone (PSF) was grafted chemically with polyethylene glycol (PEG) of different molecular weights (400, 2000, 10 000, and 20 000) and heparin to prepare PSF–PEG–Hep membranes (labeled as PSF–PEG400–Hep, PSF–PEG2000–Hep, PSF–PEG10 000–Hep, and PSF–PEG20 000–Hep). These membranes were synthesized via the following steps: (i) PSF chloromethylation; (ii) PEGylation; and (iii) heparin immobilization process. Water contact angle, critical water permeation pressure, ATR–FTIR, 1 H NMR, UV–visible spectrophotometry, and X‐ray photoelectron spectroscopy were conducted to prove grafting success and to fix the optimal reaction parameters during chemical modification processes. To further evaluate the application potential of the PSF–PEG–Hep membrane in a membrane oxygenator, we conducted pure CO2 and O2 gas permeation tests and measured the gas exchange rates of CO2 and O2 through a membrane oxygenator using fresh porcine blood. Meanwhile, the hemocompatibility of the membrane was analyzed and compared by protein adsorption, platelet adhesion, and blood coagulation tests. Results of pure gas permeation experiments indicated that the excellent gas transmission properties through PSF membrane were preserved after modification. Blood oxygenation experiments through the PSF–PEG10 000–Hep membrane showed that when the flow rate of porcine blood was 1.5 L/min, CO2 and O2 exchange rates reached 102 and 110 mL/min, respectively, which could basically satisfy the gas exchangeAbstract: Polysulfone (PSF) was grafted chemically with polyethylene glycol (PEG) of different molecular weights (400, 2000, 10 000, and 20 000) and heparin to prepare PSF–PEG–Hep membranes (labeled as PSF–PEG400–Hep, PSF–PEG2000–Hep, PSF–PEG10 000–Hep, and PSF–PEG20 000–Hep). These membranes were synthesized via the following steps: (i) PSF chloromethylation; (ii) PEGylation; and (iii) heparin immobilization process. Water contact angle, critical water permeation pressure, ATR–FTIR, 1 H NMR, UV–visible spectrophotometry, and X‐ray photoelectron spectroscopy were conducted to prove grafting success and to fix the optimal reaction parameters during chemical modification processes. To further evaluate the application potential of the PSF–PEG–Hep membrane in a membrane oxygenator, we conducted pure CO2 and O2 gas permeation tests and measured the gas exchange rates of CO2 and O2 through a membrane oxygenator using fresh porcine blood. Meanwhile, the hemocompatibility of the membrane was analyzed and compared by protein adsorption, platelet adhesion, and blood coagulation tests. Results of pure gas permeation experiments indicated that the excellent gas transmission properties through PSF membrane were preserved after modification. Blood oxygenation experiments through the PSF–PEG10 000–Hep membrane showed that when the flow rate of porcine blood was 1.5 L/min, CO2 and O2 exchange rates reached 102 and 110 mL/min, respectively, which could basically satisfy the gas exchange potential of commercial membrane oxygenators. Besides, the PSF–PEG–Hep membrane has demonstrated more prominent blood compatibility than PSF. … (more)
- Is Part Of:
- Artificial organs. Volume 40:Issue 11(2016:Nov.)
- Journal:
- Artificial organs
- Issue:
- Volume 40:Issue 11(2016:Nov.)
- Issue Display:
- Volume 40, Issue 11 (2016)
- Year:
- 2016
- Volume:
- 40
- Issue:
- 11
- Issue Sort Value:
- 2016-0040-0011-0000
- Page Start:
- E219
- Page End:
- E229
- Publication Date:
- 2016-11
- Subjects:
- Membrane oxygenator -- Polysulfone -- Polyethylene glycol -- Heparin membranes -- Chemical grafting -- Gas exchange rate -- Hemocompatibility
Artificial organs -- Periodicals
617.956 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1525-1594 ↗
http://www.blackwell-synergy.com/member/institutions/issuelist.asp?journal=aor ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1111/aor.12803 ↗
- Languages:
- English
- ISSNs:
- 0160-564X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1735.052000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 2520.xml