Dielectric characterization of water glucose solutions using a transmission/reflection line method. (January 2017)
- Record Type:
- Journal Article
- Title:
- Dielectric characterization of water glucose solutions using a transmission/reflection line method. (January 2017)
- Main Title:
- Dielectric characterization of water glucose solutions using a transmission/reflection line method
- Authors:
- Juan, Carlos G.
Bronchalo, Enrique
Torregrosa, Germán
Ávila, Ernesto
García, Nicolás
Sabater-Navarro, José M. - Abstract:
- Highlights: We present a dielectric permittivity measuring method based on a transmission/reflection line. The method is tested and its proper performance is assessed. Water glucose solutions at several concentrations are measured and their dielectric permittivities are obtained. Discussion of the results is presented and conclusions regarding the future development of a non-invasive blood glucose meter based on dielectric means are offered. Abstract: Diabetes mellitus (DM) is a disease that affects millions of people worldwide. In order to be managed, it requires the individuals to measure their blood glucose level in an uncomfortable way several times every day. Thereby, a reliable non-invasive, non-painful blood glucose monitoring system is desirable. Microwave technology has been regarded previously to develop such a sensor by dielectric means, but no clear dielectric characterization of blood glucose dielectric behavior has been hitherto shown. In this paper, a novel study of the effect on the dielectric behavior of water when glucose is added is presented, as a simplified case of blood glucose dielectric behavior. Different water glucose solutions have been dielectrically characterized using a transmission/reflection line method and the effect of the changes of the glucose level in the dielectric behavior has been discussed. Conclusions concerning the development of a non-invasive blood glucose sensor are offered and their validity is discussed.
- Is Part Of:
- Biomedical signal processing and control. Volume 31(2017)
- Journal:
- Biomedical signal processing and control
- Issue:
- Volume 31(2017)
- Issue Display:
- Volume 31, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 31
- Issue:
- 2017
- Issue Sort Value:
- 2017-0031-2017-0000
- Page Start:
- 139
- Page End:
- 147
- Publication Date:
- 2017-01
- Subjects:
- Dielectric characterization -- Relative permittivity -- Glucose -- Non-invasive glucose monitoring -- Transmission/reflection line method
Signal processing -- Periodicals
Biomedical engineering -- Periodicals
Signal Processing, Computer-Assisted -- Periodicals
Image Processing, Computer-Assisted -- Periodicals
Biomedical Engineering -- Periodicals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17468094 ↗
http://www.elsevier.com/journals ↗
http://www.sciencedirect.com/science?_ob=PublicationURL&_tockey=%23TOC%2329675%232006%23999989998%23626449%23FLA%23&_cdi=29675&_pubType=J&_auth=y&_acct=C000045259&_version=1&_urlVersion=0&_userid=836873&md5=664b5cf9a57fc91971a17faf20c32ec1 ↗ - DOI:
- 10.1016/j.bspc.2016.07.011 ↗
- Languages:
- English
- ISSNs:
- 1746-8094
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2087.880400
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 352.xml