The Michigan Experience with Safety and Effectiveness of Tranexamic Acid Use in Hip and Knee Arthroplasty. (5th October 2016)
- Record Type:
- Journal Article
- Title:
- The Michigan Experience with Safety and Effectiveness of Tranexamic Acid Use in Hip and Knee Arthroplasty. (5th October 2016)
- Main Title:
- The Michigan Experience with Safety and Effectiveness of Tranexamic Acid Use in Hip and Knee Arthroplasty
- Authors:
- Hallstrom, Brian
Singal, Bonita
Cowen, Mark E.
Roberts, Karl C.
Hughes, Richard E. - Abstract:
- Abstract : Background: The efficacy of tranexamic acid (TXA) in reducing blood loss and transfusion requirements in total hip and knee arthroplasty has been well established in small controlled clinical trials and meta-analyses. The purpose of the current study was to determine the risks and benefits of TXA use in routine orthopaedic surgical practice on the basis of data from a large, statewide arthroplasty registry. Methods: From April 18, 2013, to September 30, 2014, there were 23, 236 primary total knee arthroplasty cases and 11, 489 primary total hip arthroplasty cases completed and registered in the Michigan Arthroplasty Registry Collaborative Quality Initiative (MARCQI). We evaluated the association between TXA use and hemoglobin drop, transfusion, length of stay (LOS), venous thromboembolism (VTE), readmission, and cardiovascular events by fitting mixed-effects generalized linear and mixed-effects Cox models. We used inverse probability of treatment weighting to enhance causal inference. Results: For total hip arthroplasty, TXA use was associated with a smaller drop in hemoglobin (mean difference = −0.65 g/dL; 95% confidence interval [CI] = −0.60 to −0.71 g/dL), decreased odds of blood transfusion (odds ratio [OR] = 0.72; 95% CI = 0.60 to 0.86), and decreased readmissions (OR = 0.77; 95% CI = 0.64 to 0.93) compared with no TXA use. There was no effect on VTE (hazard ratio [HR] = 0.91; 95% CI = 0.62 to 1.33), LOS (incident rate ratio [IRR] = 1.00; 95% CI = 0.97 toAbstract : Background: The efficacy of tranexamic acid (TXA) in reducing blood loss and transfusion requirements in total hip and knee arthroplasty has been well established in small controlled clinical trials and meta-analyses. The purpose of the current study was to determine the risks and benefits of TXA use in routine orthopaedic surgical practice on the basis of data from a large, statewide arthroplasty registry. Methods: From April 18, 2013, to September 30, 2014, there were 23, 236 primary total knee arthroplasty cases and 11, 489 primary total hip arthroplasty cases completed and registered in the Michigan Arthroplasty Registry Collaborative Quality Initiative (MARCQI). We evaluated the association between TXA use and hemoglobin drop, transfusion, length of stay (LOS), venous thromboembolism (VTE), readmission, and cardiovascular events by fitting mixed-effects generalized linear and mixed-effects Cox models. We used inverse probability of treatment weighting to enhance causal inference. Results: For total hip arthroplasty, TXA use was associated with a smaller drop in hemoglobin (mean difference = −0.65 g/dL; 95% confidence interval [CI] = −0.60 to −0.71 g/dL), decreased odds of blood transfusion (odds ratio [OR] = 0.72; 95% CI = 0.60 to 0.86), and decreased readmissions (OR = 0.77; 95% CI = 0.64 to 0.93) compared with no TXA use. There was no effect on VTE (hazard ratio [HR] = 0.91; 95% CI = 0.62 to 1.33), LOS (incident rate ratio [IRR] = 1.00; 95% CI = 0.97 to 1.03), or cardiovascular events (OR = 0.85; 95% CI = 0.47 to 1.52). For total knee arthroplasty, TXA was associated with a smaller drop in hemoglobin (mean difference = −0.68 g/dL; 95% CI = −0.64 to −0.71 g/dL) and one-fourth the odds of blood transfusion (OR = 0.26; 95% CI = 0.21 to 0.31). There was an association with decreased risk of VTE within 90 days after surgery (HR = 0.56; 95% CI = 0.42 to 0.73), slightly decreased LOS (IRR = 0.93; 95% CI = 0.92 to 0.95), and no association with readmissions (OR = 0.90; 95% CI = 0.79 to 1.04) or cardiovascular events (OR = 1.12; 95% CI = 0.74 to 1.71). Conclusions: In routine orthopaedic surgery practice, TXA use was associated with decreased blood loss and transfusion risk for both total knee and total hip arthroplasty, without evidence of increased risk of complications. TXA use was also associated with reduced risk of readmission among total hip arthroplasty patients and reduced risk of VTE among total knee arthroplasty patients, and did not have an adverse effect on cardiovascular complications in either group. Level of Evidence: TherapeuticLevel III . See Instructions for Authors for a complete description of levels of evidence. … (more)
- Is Part Of:
- Journal of bone and joint surgery. Volume 98:Number 19(2016)
- Journal:
- Journal of bone and joint surgery
- Issue:
- Volume 98:Number 19(2016)
- Issue Display:
- Volume 98, Issue 19 (2016)
- Year:
- 2016
- Volume:
- 98
- Issue:
- 19
- Issue Sort Value:
- 2016-0098-0019-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-10-05
- Subjects:
- Bones -- Surgery -- Periodicals
Joints -- Surgery -- Periodicals
Orthopedics -- Periodicals
Orthopedics
General Surgery
Bone Diseases
Joint Diseases
Bones -- Surgery
Joints -- Surgery
Orthopedics
Bot (anatomie)
Gewrichten
Chirurgie (geneeskunde)
Periodicals
Electronic journals
Periodicals
617.47005 - Journal URLs:
- http://www.clinicalkey.com/dura/browse/journalIssue/00219355 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00219355 ↗
http://www.ejbjs.org/contents-by-date.0.dtl ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&PAGE=toc&D=ovft&MODE=ovid&NEWS=N&AN=00002060-000000000-00000 ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.2106/JBJS.15.01010 ↗
- Languages:
- English
- ISSNs:
- 0021-9355
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.250000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 951.xml