Plan quality and dosimetric association of patient-reported rectal and urinary toxicities for prostate stereotactic body radiotherapy. Issue 1 (October 2016)
- Record Type:
- Journal Article
- Title:
- Plan quality and dosimetric association of patient-reported rectal and urinary toxicities for prostate stereotactic body radiotherapy. Issue 1 (October 2016)
- Main Title:
- Plan quality and dosimetric association of patient-reported rectal and urinary toxicities for prostate stereotactic body radiotherapy
- Authors:
- Qi, X. Sharon
Wang, Jason P.
Gomez, Caitlin L.
Shao, Weber
Xu, Xiaoqing
King, Christopher
Low, Daniel A.
Steinberg, Michael
Kupelian, Patrick - Abstract:
- Abstract: Background and purpose: To study the association between dosimetric parameters with patient-reported quality-of-life (QOL) in urinary irritative/incontinency and bowel functions for prostate stereotactic body radiotherapy (SBRT). Material and methods: The patient-reported QOL was evaluated using the Expanded Prostate Cancer Index Composite (EPIC-26). According to the progression in QOL score over 12 months, patients were assigned to one of three subgroups: score decrement, no change, or increment. The dosimetric parameters were cross-compared among subgroups in urinary and bowel domains using univariate Analysis of Variance (ANOVA). The evaluated dosimetric metrics included target volume, V100 (volume receiving 100% prescription dose); rectal volume/dose–volume endpoints, maximum/mean doses; bladder volume/dose–volume endpoints, and maximum/mean doses. Results: Patients with consistent QOL reduction in urinary irritation function were significantly associated with greater mean bladder dose, greater V85/V90/V95/V100 and D 2cc / D 10cc . Patients with QOL reduction in urinary incontinence were marginally associated with greater mean bladder dose ( p = 0.06). None of the evaluated dosimetric parameters showed a significant correlation with QOL score change in bowel function. Conclusions: Patients with large prostate size were more susceptible to QOL decrements for urinary irritative and incontinency functions. Large bladder V85/V90/V95/V100 was associated with QOLAbstract: Background and purpose: To study the association between dosimetric parameters with patient-reported quality-of-life (QOL) in urinary irritative/incontinency and bowel functions for prostate stereotactic body radiotherapy (SBRT). Material and methods: The patient-reported QOL was evaluated using the Expanded Prostate Cancer Index Composite (EPIC-26). According to the progression in QOL score over 12 months, patients were assigned to one of three subgroups: score decrement, no change, or increment. The dosimetric parameters were cross-compared among subgroups in urinary and bowel domains using univariate Analysis of Variance (ANOVA). The evaluated dosimetric metrics included target volume, V100 (volume receiving 100% prescription dose); rectal volume/dose–volume endpoints, maximum/mean doses; bladder volume/dose–volume endpoints, and maximum/mean doses. Results: Patients with consistent QOL reduction in urinary irritation function were significantly associated with greater mean bladder dose, greater V85/V90/V95/V100 and D 2cc / D 10cc . Patients with QOL reduction in urinary incontinence were marginally associated with greater mean bladder dose ( p = 0.06). None of the evaluated dosimetric parameters showed a significant correlation with QOL score change in bowel function. Conclusions: Patients with large prostate size were more susceptible to QOL decrements for urinary irritative and incontinency functions. Large bladder V85/V90/V95/V100 was associated with QOL decrements in the urinary irritative domain at 1-year after prostate SBRT. … (more)
- Is Part Of:
- Radiotherapy and oncology. Volume 121:Issue 1(2016:Oct.)
- Journal:
- Radiotherapy and oncology
- Issue:
- Volume 121:Issue 1(2016:Oct.)
- Issue Display:
- Volume 121, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 121
- Issue:
- 1
- Issue Sort Value:
- 2016-0121-0001-0000
- Page Start:
- 113
- Page End:
- 117
- Publication Date:
- 2016-10
- Subjects:
- Prostate cancer -- Stereotactic body radiotherapy (SBRT) -- Plans quality -- Quality-of-life (QOL) -- Minimally clinically important difference (MID)
Oncology -- Periodicals
Radiotherapy -- Periodicals
Tumors -- Periodicals
Medical Oncology -- Periodicals
Neoplasms -- radiotherapy -- Periodicals
Radiotherapy -- Periodicals
Radiothérapie -- Périodiques
Cancérologie -- Périodiques
Tumeurs -- Périodiques
Electronic journals
616.9940642 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01678140 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/01678140 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/01678140 ↗
http://www.estro.org/ ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiotherapy-and-oncology/ ↗ - DOI:
- 10.1016/j.radonc.2016.08.012 ↗
- Languages:
- English
- ISSNs:
- 0167-8140
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7240.790000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2423.xml