Patient-specific simulation of endovascular repair surgery with tortuous aneurysms requiring flexible stent-grafts. (October 2016)
- Record Type:
- Journal Article
- Title:
- Patient-specific simulation of endovascular repair surgery with tortuous aneurysms requiring flexible stent-grafts. (October 2016)
- Main Title:
- Patient-specific simulation of endovascular repair surgery with tortuous aneurysms requiring flexible stent-grafts
- Authors:
- Perrin, David
Badel, Pierre
Orgeas, Laurent
Geindreau, Christian
du Roscoat, Sabine rolland
Albertini, Jean-Noël
Avril, Stéphane - Abstract:
- Abstract: The rate of post-operative complications is the main drawback of endovascular repair, a technique used to treat abdominal aortic aneurysms. Complex anatomies, featuring short aortic necks and high vessel tortuosity for instance, have been proved likely prone to these complications. In this context, practitioners could benefit, at the preoperative planning stage, from a tool able to predict the post-operative position of the stent-graft, to validate their stent-graft sizing and anticipate potential complications. In consequence, the aim of this work is to prove the ability of a numerical simulation methodology to reproduce accurately the shapes of stent-grafts, with a challenging design, deployed inside tortuous aortic aneurysms. Stent-graft module samples were scanned by X-ray microtomography and subjected to mechanical tests to generate finite-element models. Two EVAR clinical cases were numerically reproduced by simulating stent-graft models deployment inside the tortuous arterial model generated from patient pre-operative scan. In the same manner, an in vitro stent-graft deployment in a rigid polymer phantom, generated by extracting the arterial geometry from the preoperative scan of a patient, was simulated to assess the influence of biomechanical environment unknowns in the in vivo case. Results were validated by comparing stent positions on simulations and post-operative scans. In all cases, simulation predicted stents deployed locations and shapes with anAbstract: The rate of post-operative complications is the main drawback of endovascular repair, a technique used to treat abdominal aortic aneurysms. Complex anatomies, featuring short aortic necks and high vessel tortuosity for instance, have been proved likely prone to these complications. In this context, practitioners could benefit, at the preoperative planning stage, from a tool able to predict the post-operative position of the stent-graft, to validate their stent-graft sizing and anticipate potential complications. In consequence, the aim of this work is to prove the ability of a numerical simulation methodology to reproduce accurately the shapes of stent-grafts, with a challenging design, deployed inside tortuous aortic aneurysms. Stent-graft module samples were scanned by X-ray microtomography and subjected to mechanical tests to generate finite-element models. Two EVAR clinical cases were numerically reproduced by simulating stent-graft models deployment inside the tortuous arterial model generated from patient pre-operative scan. In the same manner, an in vitro stent-graft deployment in a rigid polymer phantom, generated by extracting the arterial geometry from the preoperative scan of a patient, was simulated to assess the influence of biomechanical environment unknowns in the in vivo case. Results were validated by comparing stent positions on simulations and post-operative scans. In all cases, simulation predicted stents deployed locations and shapes with an accuracy of a few millimetres. The good results obtained in the in vitro case validated the ability of the methodology to simulate stent-graft deployment in very tortuous arteries and led to think proper modelling of biomechanical environment could reduce the few local discrepancies found in the in vivo case. In conclusion, this study proved that our methodology can achieve accurate simulation of stent-graft deployed shape even in tortuous patient specific aortic aneurysms and may be potentially helpful to help practitioners plan their intervention. Graphical abstract: Highlights: Stent-graft samples were mechanically tested and digitised by microtomography scan. FE analysis was used to model stent-graft deployment in patient-specific aneurysms. The methodology was first evaluated by simulating in silico an in vitro deployment. Simulations were then compared to postoperative images for two clinical cases. The quantitative comparison showed simulation accuracy in tortuous anatomies. … (more)
- Is Part Of:
- Journal of the mechanical behavior of biomedical materials. Volume 63(2016)
- Journal:
- Journal of the mechanical behavior of biomedical materials
- Issue:
- Volume 63(2016)
- Issue Display:
- Volume 63, Issue 2016 (2016)
- Year:
- 2016
- Volume:
- 63
- Issue:
- 2016
- Issue Sort Value:
- 2016-0063-2016-0000
- Page Start:
- 86
- Page End:
- 99
- Publication Date:
- 2016-10
- Subjects:
- Endovascular repair -- Abdominal aortic aneurysm -- Stent-graft -- Patient-specific -- Finite-element analysis
Biomedical materials -- Periodicals
Biomedical materials -- Mechanical properties -- Periodicals
Biomedical materials
Biomedical materials -- Mechanical properties
Periodicals
Electronic journals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17516161 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jmbbm.2016.06.013 ↗
- Languages:
- English
- ISSNs:
- 1751-6161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5015.809000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1058.xml