Buried absorbable polyglactin 910 sutures do not result in stronger wounds in porcine full thickness skin incisions. (October 2016)
- Record Type:
- Journal Article
- Title:
- Buried absorbable polyglactin 910 sutures do not result in stronger wounds in porcine full thickness skin incisions. (October 2016)
- Main Title:
- Buried absorbable polyglactin 910 sutures do not result in stronger wounds in porcine full thickness skin incisions
- Authors:
- Townsend, Katy L.
Lear, William
Robertson, Bria L.
Kruzic, Jamie J. - Abstract:
- Abstract: Objective: To test the hypothesis that the mechanical strength of wounds closed with a combination of buried dermal absorbable sutures and superficial nonabsorbable nylon sutures will be higher than wounds closed with only superficial nonabsorbable nylon sutures. Methods: Four Yucatan pigs were anesthetized and each received four 4.5 cm full thickness incisions on their dorsal surfaces, placed 8 cm apart. Half of all incisions were randomly allocated and repaired with 3–0 polyglactin 910 (Vicryl ™ ) buried dermal absorbable sutures and superficial 3–0 nylon sutures, using a simple interrupted pattern. The other half received only 3–0 nylon sutures. Two pigs were humanely euthanized at day 10, with specimen harvest for mechanical testing; the other two pigs had superficial nylon sutures removed at day 10, as per current clinical practice, and were humanely euthanized at day 42, with specimen harvest for mechanical testing. Tensile loads were applied perpendicularly to the wounds with a displacement rate of 40 mm per minute. Results: Wounds at day 42 were >9 times stronger than wounds at day 10 ( p <0.0001). There was no difference in average wound strength at either day 10 or day 42 between wounds with and without buried dermal absorbable sutures. Significance: Buried dermal absorbable sutures failed to provide additional wound support at either 10 or 42 days. This result may have immediate implications for clinicians who perform cutaneous surgery and keepAbstract: Objective: To test the hypothesis that the mechanical strength of wounds closed with a combination of buried dermal absorbable sutures and superficial nonabsorbable nylon sutures will be higher than wounds closed with only superficial nonabsorbable nylon sutures. Methods: Four Yucatan pigs were anesthetized and each received four 4.5 cm full thickness incisions on their dorsal surfaces, placed 8 cm apart. Half of all incisions were randomly allocated and repaired with 3–0 polyglactin 910 (Vicryl ™ ) buried dermal absorbable sutures and superficial 3–0 nylon sutures, using a simple interrupted pattern. The other half received only 3–0 nylon sutures. Two pigs were humanely euthanized at day 10, with specimen harvest for mechanical testing; the other two pigs had superficial nylon sutures removed at day 10, as per current clinical practice, and were humanely euthanized at day 42, with specimen harvest for mechanical testing. Tensile loads were applied perpendicularly to the wounds with a displacement rate of 40 mm per minute. Results: Wounds at day 42 were >9 times stronger than wounds at day 10 ( p <0.0001). There was no difference in average wound strength at either day 10 or day 42 between wounds with and without buried dermal absorbable sutures. Significance: Buried dermal absorbable sutures failed to provide additional wound support at either 10 or 42 days. This result may have immediate implications for clinicians who perform cutaneous surgery and keep superficial sutures in for at least 10 days. Future research will be directed to shorter time studies, other buried dermal absorbable suture materials, and alternatives to buried dermal absorbable sutures. Graphical abstract: Highlights: Wounds at day 42 were >9 times stronger than day 10. Buried dermal absorbable sutures do not increase wound strength at days 10 and 42. Little advantage for use of buried dermal absorbable sutures in wounds. … (more)
- Is Part Of:
- Journal of the mechanical behavior of biomedical materials. Volume 63(2016)
- Journal:
- Journal of the mechanical behavior of biomedical materials
- Issue:
- Volume 63(2016)
- Issue Display:
- Volume 63, Issue 2016 (2016)
- Year:
- 2016
- Volume:
- 63
- Issue:
- 2016
- Issue Sort Value:
- 2016-0063-2016-0000
- Page Start:
- 386
- Page End:
- 389
- Publication Date:
- 2016-10
- Subjects:
- Wound -- Strength -- Buried suture -- Pig -- Polyglactin 910
Biomedical materials -- Periodicals
Biomedical materials -- Mechanical properties -- Periodicals
Biomedical materials
Biomedical materials -- Mechanical properties
Periodicals
Electronic journals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17516161 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jmbbm.2016.06.033 ↗
- Languages:
- English
- ISSNs:
- 1751-6161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5015.809000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1058.xml