ECG predictors of T wave oversensing in subcutaneous implantable cardioverter defibrillators. (1st October 2016)
- Record Type:
- Journal Article
- Title:
- ECG predictors of T wave oversensing in subcutaneous implantable cardioverter defibrillators. (1st October 2016)
- Main Title:
- ECG predictors of T wave oversensing in subcutaneous implantable cardioverter defibrillators
- Authors:
- Wilson, D.G.
Leventigiannis, G.
Barr, C.
Morgan, J.M. - Abstract:
- Abstract: Background: T wave oversensing (TWOS) is the commonest cause of inappropriate shocks in subcutaneous implantable cardioverter defibrillators (S-ICDs). We hypothesise that predictors of TWOS can be derived from surface ECG parameters. Methods: In a cohort of SICD recipients in two UK centres, all patients who had TWOS (study group) were compared to all those who had not (control group). The pre-implant screen was scanned and the R wave, T wave amplitudes, QRS interval, time to peak T wave, QT interval and R:T ratio was measured using digital callipers. Logistic regression was performed to identify ECG predictors of TWOS. Results: One hundred one patients were studied. Six (5.9%) had TWOS. The mean age of the population was 58.6 ± 18 years and the median follow-up was 19.5 months. By univariate analysis, the predictors of TWOS are QRS duration (140.7 ± 28.7 vs. 105.9 ± 24.6, P = 0.007), time to peak T wave (corrected for heart rate, pTc) (403.9 ± 22.6 vs. 347.8 ± 41.4, P = 0.006), QTc interval (500.4 ± 41.2 vs. 446.8 ± 49.7, P = 0.021), and R:T ratio (3.5 ± 1.1 vs. 9.5 ± 13.2, P = 0.034). By multivariate analysis, time to pTc is the most predictive of TWOS. A time to pTc of 390 ms cut-off point provided a sensitivity 38.5%, a specificity of 98.9%, a positive predictive value for TWOS of 83.3%, and a negative predictive value of 91.6% (AUC = 0.687). Conclusion: In this study, time to pTc is the most powerful ECG predictor of TWOS.
- Is Part Of:
- International journal of cardiology. Volume 220(2016)
- Journal:
- International journal of cardiology
- Issue:
- Volume 220(2016)
- Issue Display:
- Volume 220, Issue 2016 (2016)
- Year:
- 2016
- Volume:
- 220
- Issue:
- 2016
- Issue Sort Value:
- 2016-0220-2016-0000
- Page Start:
- 27
- Page End:
- 31
- Publication Date:
- 2016-10-01
- Subjects:
- Subcutaneous implantable cardioverter defibrillator -- T wave oversensing -- Electrocardiogram -- Inappropriate shock -- Predictors
Cardiology -- Periodicals
Electronic journals
616.12 - Journal URLs:
- http://www.clinicalkey.com/dura/browse/journalIssue/01675273 ↗
http://www.sciencedirect.com/science/journal/01675273 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijcard.2016.06.128 ↗
- Languages:
- English
- ISSNs:
- 0167-5273
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.158000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 413.xml