Experimental study of a novel double temperature chiller based on R32/R236fa. (15th September 2016)
- Record Type:
- Journal Article
- Title:
- Experimental study of a novel double temperature chiller based on R32/R236fa. (15th September 2016)
- Main Title:
- Experimental study of a novel double temperature chiller based on R32/R236fa
- Authors:
- Liu, Jian
She, Xiaohui
Zhang, Xiaosong
Man, Liang
Zhou, Wei - Abstract:
- Highlights: A novel double-temperature chiller with zeotropic mixture R32 / R236fa is proposed. The chiller is applicable for temperature and humidity independent control system. Effects of mass fraction, fluid flow rate and temperature on chiller are studied. The suggested mass fraction of R32 is around 60%. The maximum COP and refrigerating capacity are 4.17 and 4.49 kW, respectively. Abstract: A novel double-temperature chiller with zeotropic mixture R32/R236fa is proposed in this paper, and chilled water with two different temperatures is produced, such as low temperature water ( TL, out = 7 °C) and high temperature water ( TH, out = 16 °C). An experimental setup is established to test the performance of the chiller. Effects of mass fraction of R32 in mixture R32/R236fa ( M (R32)), TL, out, TH, out and the heat transfer media flow rate on the performance of the chiller are studied. When TH, out is 18 °C, TL, out is 8 °C and M (R32) is 0.6, COP and refrigerating capacity are 4.11 and 4.42 kW, respectively. COP and refrigerating capacity increase as M (R32) increases. Exhausting pressure of the chiller increases with the increase of M (R32). As M (R32) is 0.6, exhausting pressure is about 1.95 MPa. Compression ratio decreases with the increase of M (R32). When M (R32) increases from 0.3 to 0.6, the compression ratio decreases from 3.0 to 2.9.
- Is Part Of:
- Energy conversion and management. Volume 124(2016)
- Journal:
- Energy conversion and management
- Issue:
- Volume 124(2016)
- Issue Display:
- Volume 124, Issue 2016 (2016)
- Year:
- 2016
- Volume:
- 124
- Issue:
- 2016
- Issue Sort Value:
- 2016-0124-2016-0000
- Page Start:
- 618
- Page End:
- 626
- Publication Date:
- 2016-09-15
- Subjects:
- Zeotropic refrigerant -- Water chiller -- Double temperature -- Mass fraction -- THIC
Direct energy conversion -- Periodicals
Energy storage -- Periodicals
Energy transfer -- Periodicals
Énergie -- Conversion directe -- Périodiques
Direct energy conversion
Periodicals
621.3105 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01968904 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.enconman.2016.06.023 ↗
- Languages:
- English
- ISSNs:
- 0196-8904
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3747.547000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1199.xml