P16. Dose distribution comparison of XiO simulated bolus vs. physically scanned bolus for head and neck patients with mask at Tygerberg Hospital. (September 2016)
- Record Type:
- Journal Article
- Title:
- P16. Dose distribution comparison of XiO simulated bolus vs. physically scanned bolus for head and neck patients with mask at Tygerberg Hospital. (September 2016)
- Main Title:
- P16. Dose distribution comparison of XiO simulated bolus vs. physically scanned bolus for head and neck patients with mask at Tygerberg Hospital
- Authors:
- Mkhize, T.
Mohlapholi, M.
Toit, M. du - Abstract:
- Abstract : Introduction: Bolus is a tissue equivalent material that can be placed on the skin to increase dose received at depth in patient and on the skin surface. At the radiotherapy planning department, the bolus is used to improve the tumour coverage by bringing the dose (95% isodose curve) closer to the skin (mainly for superficial tumours) for head and neck patients. It is added on the TPS to the CT acquired image with mask on. The concern arose that the XiO TPS might not calculate the dose distribution correctly with the bolus added after the patient is imaged with the mask on. Materials and methods: A Rando phantom with and without bolus was scanned on the Philips Brilliance Big Bore CT using head and neck protocol. The bolus material was a super flab with density of 1.02 g/cm 3 and thickness of 0.5 cm. At CMS XiO, plans with one beam perpendicular to the phantom entering at 0° were generated. The generated plans used SAD method with 10 × 10 cm 2 field sizes on the surface. A dose of 1 Gy, normalized to 100% of Isodose curve (line) was prescribed for a 6 MV beam. Three interest points 0.5 cm apart at 1.5 cm depth were measured and their dose distributions and point doses compared. Results: The XiO drawn bolus and physically scanned bolus plan's dose distributions compared well when superimposed to one another, and their percentage error difference was ±2.35%. Conclusion: For both dose distribution and point dose measurements, results showed a good correlation betweenAbstract : Introduction: Bolus is a tissue equivalent material that can be placed on the skin to increase dose received at depth in patient and on the skin surface. At the radiotherapy planning department, the bolus is used to improve the tumour coverage by bringing the dose (95% isodose curve) closer to the skin (mainly for superficial tumours) for head and neck patients. It is added on the TPS to the CT acquired image with mask on. The concern arose that the XiO TPS might not calculate the dose distribution correctly with the bolus added after the patient is imaged with the mask on. Materials and methods: A Rando phantom with and without bolus was scanned on the Philips Brilliance Big Bore CT using head and neck protocol. The bolus material was a super flab with density of 1.02 g/cm 3 and thickness of 0.5 cm. At CMS XiO, plans with one beam perpendicular to the phantom entering at 0° were generated. The generated plans used SAD method with 10 × 10 cm 2 field sizes on the surface. A dose of 1 Gy, normalized to 100% of Isodose curve (line) was prescribed for a 6 MV beam. Three interest points 0.5 cm apart at 1.5 cm depth were measured and their dose distributions and point doses compared. Results: The XiO drawn bolus and physically scanned bolus plan's dose distributions compared well when superimposed to one another, and their percentage error difference was ±2.35%. Conclusion: For both dose distribution and point dose measurements, results showed a good correlation between each other. This assured us that XiO bolus was been considered by our TPS when calculating. … (more)
- Is Part Of:
- Physica medica. Volume 32(2016)Supplement 2
- Journal:
- Physica medica
- Issue:
- Volume 32(2016)Supplement 2
- Issue Display:
- Volume 32, Issue 2 (2016)
- Year:
- 2016
- Volume:
- 32
- Issue:
- 2
- Issue Sort Value:
- 2016-0032-0002-0000
- Page Start:
- 165
- Page End:
- 166
- Publication Date:
- 2016-09
- Subjects:
- Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2016.07.083 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 84.xml