Impact of Prosthesis Length on Tympanic Membrane's and Annular Ligament's Stiffness and the Resulting Middle Ear Sound Transmission. Issue 9 (October 2016)
- Record Type:
- Journal Article
- Title:
- Impact of Prosthesis Length on Tympanic Membrane's and Annular Ligament's Stiffness and the Resulting Middle Ear Sound Transmission. Issue 9 (October 2016)
- Main Title:
- Impact of Prosthesis Length on Tympanic Membrane's and Annular Ligament's Stiffness and the Resulting Middle Ear Sound Transmission
- Authors:
- Neudert, Marcus
Bornitz, Matthias
Lasurashvili, Nikoloz
Schmidt, Uwe
Beleites, Thomas
Zahnert, Thomas - Abstract:
- Abstract : Supplemental Digital Content is available in the text Abstract : Hypothesis: Prosthesis' length creates tension in ossicular reconstructions, which directly effects the middle ear sound transmission. Background: Relatively long prostheses are often used to stabilize the middle ear reconstruction to prevent dislocation. Thereby, tension on the flexible components such as the tympanic membrane (TM) and the annular ligament (AL) is increased. Only little is known on the amount of displacement-related stiffening of the TM and AL, as well as the consecutive reduction in middle ear transfer function (METF). Methods: An expandable total ossicular replacement prosthesis was tensionfree inserted in nine cadaveric temporal bones between the malleus handle and the stapes footplate. Upon heat activation the prosthesis was lengthened, thus inducing tension on the reconstruction. The METF was assessed before and after elongation. TM's and AL's stiffness were determined by measuring their force–displacement characteristics. Results: Upon activation the prostheses were elongated between 50 and 200 μm. A frequency-dependent METF reduction was measured with a decrease of 5 to 25 dB below 1.0 kHz. At frequencies >2.0 kHz the reduction was less prominent or the METF showed even an improvement of up to 10 dB. TM's stiffness remained constant during the elongation-induced displacement, whereas the AL's stiffness increased. The METF reduction below 1.0 kHz correlated with the increasingAbstract : Supplemental Digital Content is available in the text Abstract : Hypothesis: Prosthesis' length creates tension in ossicular reconstructions, which directly effects the middle ear sound transmission. Background: Relatively long prostheses are often used to stabilize the middle ear reconstruction to prevent dislocation. Thereby, tension on the flexible components such as the tympanic membrane (TM) and the annular ligament (AL) is increased. Only little is known on the amount of displacement-related stiffening of the TM and AL, as well as the consecutive reduction in middle ear transfer function (METF). Methods: An expandable total ossicular replacement prosthesis was tensionfree inserted in nine cadaveric temporal bones between the malleus handle and the stapes footplate. Upon heat activation the prosthesis was lengthened, thus inducing tension on the reconstruction. The METF was assessed before and after elongation. TM's and AL's stiffness were determined by measuring their force–displacement characteristics. Results: Upon activation the prostheses were elongated between 50 and 200 μm. A frequency-dependent METF reduction was measured with a decrease of 5 to 25 dB below 1.0 kHz. At frequencies >2.0 kHz the reduction was less prominent or the METF showed even an improvement of up to 10 dB. TM's stiffness remained constant during the elongation-induced displacement, whereas the AL's stiffness increased. The METF reduction below 1.0 kHz correlated with the increasing AL's stiffness. Conclusion: Tension has a significant impact on the METF after middle ear reconstruction. As little tension as possible should be used to enable best sound transmission. Stabilization of prosthesis should be achieved with dislocation devices to ensure secure coupling to the ossicular remnants without creating additional tension. … (more)
- Is Part Of:
- Otology & neurotology. Volume 37:Issue 9(2016)
- Journal:
- Otology & neurotology
- Issue:
- Volume 37:Issue 9(2016)
- Issue Display:
- Volume 37, Issue 9 (2016)
- Year:
- 2016
- Volume:
- 37
- Issue:
- 9
- Issue Sort Value:
- 2016-0037-0009-0000
- Page Start:
- e369
- Page End:
- e376
- Publication Date:
- 2016-10
- Subjects:
- Annular ligament -- Middle ear transfer function -- Ossicular reconstruction -- Prosthesis length -- Sound transmission -- Tension
Otology -- Periodicals
Ear -- Diseases -- Periodicals
Skull base -- Surgery -- Periodicals
617.8005 - Journal URLs:
- http://www.otology-neurotology.com ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MAO.0000000000001064 ↗
- Languages:
- English
- ISSNs:
- 1531-7129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6313.528000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 932.xml