High definition urethral pressure profilometry: Evaluating a novel microtip catheter. Issue 8 (24th July 2015)
- Record Type:
- Journal Article
- Title:
- High definition urethral pressure profilometry: Evaluating a novel microtip catheter. Issue 8 (24th July 2015)
- Main Title:
- High definition urethral pressure profilometry: Evaluating a novel microtip catheter
- Authors:
- Klünder, Mario
Amend, Bastian
Vaegler, Martin
Kelp, Alexandra
Feuer, Ronny
Sievert, Karl‐Dietrich
Stenzl, Arnulf
Sawodny, Oliver
Ederer, Michael - Abstract:
- Abstract : Introduction: Urethral pressure profilometry (UPP) is used in the diagnosis of stress urinary incontinence (SUI). SUI is a significant medical, social, and economic problem, affecting about 12.5% of the population. A novel microtip catheter was developed for UPP featuring an inclination sensor and higher angular resolution compared to systems in clinical use today. Therewith, the location of each measured pressure sample can be determined and the spatial pressure distribution inside the urethra reconstructed. In order to assess the performance and plausibility of data from the microtip catheter, we compare it to data from a double balloon air charged system. Materials and Methods: Both catheters are used on sedated female minipigs. Data from the microtip catheter are processed through a signal reconstruction algorithm, plotted and compared against data from the air‐charged catheter. Results: The microtip catheter delivers results in agreement with previous comparisons of microtip and air‐charged systems. It additionally provides a new level of detail in the reconstructed UPPs which may lead to new insights into the sphincter mechanism of minipigs. Conclusions: The ability of air‐charged catheters to measure pressure circumferentially is widely considered a main advantage over microtip catheters. However, directional pressure readings can provide additional information on angular fluctuations in the urethral pressure distribution. It is shown that the novelAbstract : Introduction: Urethral pressure profilometry (UPP) is used in the diagnosis of stress urinary incontinence (SUI). SUI is a significant medical, social, and economic problem, affecting about 12.5% of the population. A novel microtip catheter was developed for UPP featuring an inclination sensor and higher angular resolution compared to systems in clinical use today. Therewith, the location of each measured pressure sample can be determined and the spatial pressure distribution inside the urethra reconstructed. In order to assess the performance and plausibility of data from the microtip catheter, we compare it to data from a double balloon air charged system. Materials and Methods: Both catheters are used on sedated female minipigs. Data from the microtip catheter are processed through a signal reconstruction algorithm, plotted and compared against data from the air‐charged catheter. Results: The microtip catheter delivers results in agreement with previous comparisons of microtip and air‐charged systems. It additionally provides a new level of detail in the reconstructed UPPs which may lead to new insights into the sphincter mechanism of minipigs. Conclusions: The ability of air‐charged catheters to measure pressure circumferentially is widely considered a main advantage over microtip catheters. However, directional pressure readings can provide additional information on angular fluctuations in the urethral pressure distribution. It is shown that the novel microtip catheter in combination with a signal reconstruction algorithm delivers plausible data. It offers the opportunity to evaluate urethral structures, especially the sphincter, in context of the correct location within the anatomical location of the pelvic floor. Neurourol. Urodynam. 35:888–894, 2016 . © 2015 Wiley Periodicals, Inc. … (more)
- Is Part Of:
- Neurourology and urodynamics. Volume 35:Issue 8(2016:Nov.)
- Journal:
- Neurourology and urodynamics
- Issue:
- Volume 35:Issue 8(2016:Nov.)
- Issue Display:
- Volume 35, Issue 8 (2016)
- Year:
- 2016
- Volume:
- 35
- Issue:
- 8
- Issue Sort Value:
- 2016-0035-0008-0000
- Page Start:
- 888
- Page End:
- 894
- Publication Date:
- 2015-07-24
- Subjects:
- digital signal processing -- urodynamics -- urethral pressure -- urinary catheters
Urinary organs -- Periodicals
Urodynamics -- Periodicals
Urology -- Periodicals
616.6 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1520-6777 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/nau.22835 ↗
- Languages:
- English
- ISSNs:
- 0733-2467
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6081.589000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1980.xml