Biomechanical interactions of different mini-plate fixations and maxilla advancements in the Le Fort I Osteotomy: a finite element analysis. Issue 16 (9th December 2016)
- Record Type:
- Journal Article
- Title:
- Biomechanical interactions of different mini-plate fixations and maxilla advancements in the Le Fort I Osteotomy: a finite element analysis. Issue 16 (9th December 2016)
- Main Title:
- Biomechanical interactions of different mini-plate fixations and maxilla advancements in the Le Fort I Osteotomy: a finite element analysis
- Authors:
- Huang, Shao-Fu
Lo, Lun-Jou
Lin, Chun-Li - Abstract:
- Abstract: This study investigates the biomechanical interaction of different mini-plate fixation types (shapes/sizes and patterns) with segmental advancement levels on the Le Fort I osteotomy using the non-linear finite element (FE) approach. Nine models were generated under a standard 1-piece LeFort I osteotomy for advancement with 3, 6 and 9 mm distances and four mini-plates with three fixation patterns including LL, LI, and II patterns placed on the maxillae models by integrating computed tomography images and computer-aided design system. The axial and oblique occlusal forces were 250 N applied to each premolar/molar and 125 N applied at 30° inclination to the tooth long axis and from palatal to buccal, respectively. The relative micro-movement values between the two maxillary bone segments and maximum mini-plate stress increased obviously with maxilla advancement increment and the increasing trend can be fitted by exponential curve. The corresponding values in II mini-plate fixation presented apparently high values in all simulated cases. The mini-plate stress concentration locations were found at the bending regions to increase high fracture risk. The mini-plate yield strength can be mapped to a critical (limited) advancement for three types of fixations for safe consideration. This study concluded that L-shaped mini-plates with lateral fixation are recommended to provide better stability. The risk for mini-plate fracture and bone relapse increases when maxillaryAbstract: This study investigates the biomechanical interaction of different mini-plate fixation types (shapes/sizes and patterns) with segmental advancement levels on the Le Fort I osteotomy using the non-linear finite element (FE) approach. Nine models were generated under a standard 1-piece LeFort I osteotomy for advancement with 3, 6 and 9 mm distances and four mini-plates with three fixation patterns including LL, LI, and II patterns placed on the maxillae models by integrating computed tomography images and computer-aided design system. The axial and oblique occlusal forces were 250 N applied to each premolar/molar and 125 N applied at 30° inclination to the tooth long axis and from palatal to buccal, respectively. The relative micro-movement values between the two maxillary bone segments and maximum mini-plate stress increased obviously with maxilla advancement increment and the increasing trend can be fitted by exponential curve. The corresponding values in II mini-plate fixation presented apparently high values in all simulated cases. The mini-plate stress concentration locations were found at the bending regions to increase high fracture risk. The mini-plate yield strength can be mapped to a critical (limited) advancement for three types of fixations for safe consideration. This study concluded that L-shaped mini-plates with lateral fixation are recommended to provide better stability. The risk for mini-plate fracture and bone relapse increases when maxillary advancement is larger than a critical value of 5 mm in the Le Fort I osteotomy. … (more)
- Is Part Of:
- Computer methods in biomechanics and biomedical engineering. Volume 19:Issue 16(2016)
- Journal:
- Computer methods in biomechanics and biomedical engineering
- Issue:
- Volume 19:Issue 16(2016)
- Issue Display:
- Volume 19, Issue 16 (2016)
- Year:
- 2016
- Volume:
- 19
- Issue:
- 16
- Issue Sort Value:
- 2016-0019-0016-0000
- Page Start:
- 1704
- Page End:
- 1713
- Publication Date:
- 2016-12-09
- Subjects:
- Finite element -- Le Fort I osteotomy -- mini-plate -- fixation -- advancement
Biomechanics -- Data processing -- Periodicals
Biomedical engineering -- Periodicals
Biomechanics -- Periodicals
Biomedical Engineering -- methods -- Periodicals
Computing Methodologies -- Periodicals
612.7 - Journal URLs:
- http://www.tandfonline.com/toc/gcmb20/current ↗
http://www.tandfonline.com/ ↗ - DOI:
- 10.1080/10255842.2016.1182631 ↗
- Languages:
- English
- ISSNs:
- 1025-5842
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3394.100250
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 851.xml