Stroke incidence in patients with cardiac implantable electronic devices remotely controlled with automatic alerts of atrial fibrillation. A sub-analysis of the HomeGuide study. (15th September 2016)
- Record Type:
- Journal Article
- Title:
- Stroke incidence in patients with cardiac implantable electronic devices remotely controlled with automatic alerts of atrial fibrillation. A sub-analysis of the HomeGuide study. (15th September 2016)
- Main Title:
- Stroke incidence in patients with cardiac implantable electronic devices remotely controlled with automatic alerts of atrial fibrillation. A sub-analysis of the HomeGuide study
- Authors:
- Ricci, Renato Pietro
Vaccari, Diego
Morichelli, Loredana
Zanotto, Gabriele
Calò, Leonardo
D'Onofrio, Antonio
Curnis, Antonio
Pisanò, Ennio C.L.
Nangah, René
Brieda, Marco
Calzolari, Vittorio
Melissano, Donato
Rovai, Nicola
Gargaro, Alessio - Abstract:
- Abstract : Background : Remote Monitoring (RM) of cardiac implantable electronic devices (CIEDs) is recommended in management of Atrial Fibrillation (AF), which is a recognized risk factor for thromboembolism. We tried to elucidate whether stroke incidence observed in a large, remotely monitored population was consistent with the CHA2 DS2 VASc risk profile. Methods : Data from 1650 patients [76% male, age 72 (63–68), CHA2 DS2 VASc score 3.0 (2.0–4.0)] enrolled during the HomeGuide study and monitored with a daily-transmission RM system providing automatic alerts for AF, were analysed. Of those, 25% had a pacemaker and 75% an implantable cardioverter defibrillator with or without cardiac resynchronization. Estimations of the expected thromboembolic events were based on the population CHA2 DS2 VASc score profile used in a computer-simulated Markov model. Results : Eight thromboembolic events were observed with a 4-year cumulative stroke rate of 0.8% (confidence interval, 0.4%–1.5%). Simulations returned from 18.7 to 17.1 expected events, depending on the AF duration assumed to trigger anticoagulation (one-sample log-rank p < 0.03). During the study period, 681 (84%) AF episodes and 129 (16%) atrial tachycardias were detected in 291 patients (18%): 93% of episodes were detected remotely in 269 patients, 66% of whom had no history of AF. Medical interventions were necessary in 305 episodes, 85% of which were detected remotely. Reaction time was 1 (0–6) days for remotely-detectedAbstract : Background : Remote Monitoring (RM) of cardiac implantable electronic devices (CIEDs) is recommended in management of Atrial Fibrillation (AF), which is a recognized risk factor for thromboembolism. We tried to elucidate whether stroke incidence observed in a large, remotely monitored population was consistent with the CHA2 DS2 VASc risk profile. Methods : Data from 1650 patients [76% male, age 72 (63–68), CHA2 DS2 VASc score 3.0 (2.0–4.0)] enrolled during the HomeGuide study and monitored with a daily-transmission RM system providing automatic alerts for AF, were analysed. Of those, 25% had a pacemaker and 75% an implantable cardioverter defibrillator with or without cardiac resynchronization. Estimations of the expected thromboembolic events were based on the population CHA2 DS2 VASc score profile used in a computer-simulated Markov model. Results : Eight thromboembolic events were observed with a 4-year cumulative stroke rate of 0.8% (confidence interval, 0.4%–1.5%). Simulations returned from 18.7 to 17.1 expected events, depending on the AF duration assumed to trigger anticoagulation (one-sample log-rank p < 0.03). During the study period, 681 (84%) AF episodes and 129 (16%) atrial tachycardias were detected in 291 patients (18%): 93% of episodes were detected remotely in 269 patients, 66% of whom had no history of AF. Medical interventions were necessary in 305 episodes, 85% of which were detected remotely. Reaction time was 1 (0–6) days for remotely-detected episodes and 33 (14–121) days for episodes detected in clinic (p < 0.0001). Conclusions : In a large CIED population followed remotely for up to 4 years, the incidence of thromboembolic events was less than half the estimations based on the CHA2 DS2 VASc risk profile. … (more)
- Is Part Of:
- International journal of cardiology. Volume 219(2016)
- Journal:
- International journal of cardiology
- Issue:
- Volume 219(2016)
- Issue Display:
- Volume 219, Issue 2016 (2016)
- Year:
- 2016
- Volume:
- 219
- Issue:
- 2016
- Issue Sort Value:
- 2016-0219-2016-0000
- Page Start:
- 251
- Page End:
- 256
- Publication Date:
- 2016-09-15
- Subjects:
- Pacemakers -- Implantable cardioverter defibrillators -- Remote monitoring -- Telemedicine -- Atrial fibrillation -- Stroke
Cardiology -- Periodicals
Electronic journals
616.12 - Journal URLs:
- http://www.clinicalkey.com/dura/browse/journalIssue/01675273 ↗
http://www.sciencedirect.com/science/journal/01675273 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijcard.2016.06.016 ↗
- Languages:
- English
- ISSNs:
- 0167-5273
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.158000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1008.xml