Right ventricular function following surgical aortic valve replacement and transcatheter aortic valve implantation: A cardiovascular MR study. (15th November 2016)
- Record Type:
- Journal Article
- Title:
- Right ventricular function following surgical aortic valve replacement and transcatheter aortic valve implantation: A cardiovascular MR study. (15th November 2016)
- Main Title:
- Right ventricular function following surgical aortic valve replacement and transcatheter aortic valve implantation: A cardiovascular MR study
- Authors:
- Musa, Tarique Al
Uddin, Akhlaque
Fairbairn, Timothy A.
Dobson, Laura E.
Steadman, Christopher D.
Kidambi, Ananth
Ripley, David P.
Swoboda, Peter P.
McDiarmid, Adam K.
Erhayiem, Bara
Garg, Pankaj
Blackman, Daniel J.
Plein, Sven
McCann, Gerald P.
Greenwood, John P. - Abstract:
- Abstract: Objective: The response of the RV following treatment of aortic stenosis is poorly defined, reflecting the challenge of accurate RV assessment. Cardiovascular magnetic resonance (CMR) is the established reference for imaging of RV volumes, mass and function. We sought to define the impact of transcatheter aortic valve implantation (TAVI) and surgical aortic valve replacement (SAVR) upon RV function in patients treated for severe aortic stenosis using CMR. Methods: A 1.5T CMR scan was performed preoperatively and 6 months postoperatively in 112 (56 TAVI, 56 SAVR; 76 ± 8 years) high-risk severe symptomatic aortic stenosis patients across two UK cardiothoracic centres. Results: TAVI patients were older (80.4 ± 6.7 vs. 72.8 ± 7.2 years, p < 0.05) with a higher STS score (2.13 ± 0.73 vs. 5.54 ± 3.41%, p < 0.001). At 6 months, SAVR was associated with a significant increase in RV end systolic volume (33 ± 10 vs. 37 ± 10 ml/m 2, p = 0.008), and decrease in RV ejection fraction (58 ± 8 vs. 53 ± 8%, p = 0.005) and tricuspid annular plane systolic excursion (22 ± 5 vs. 14 ± 3 mm, p < 0.001). Only 4 (7%) SAVR patients had new RV late gadolinium hyper-enhancement with no new cases seen in the TAVI patients at 6 months. Longer surgical cross-clamp time was the only predictor of increased RV end systolic volume at 6 months. Post-TAVI, there was no observed change in RV volumes or function. Over a maximum 6.3 year follow-up, 18(32%) of TAVI patients and 1(1.7%) of SAVR patientsAbstract: Objective: The response of the RV following treatment of aortic stenosis is poorly defined, reflecting the challenge of accurate RV assessment. Cardiovascular magnetic resonance (CMR) is the established reference for imaging of RV volumes, mass and function. We sought to define the impact of transcatheter aortic valve implantation (TAVI) and surgical aortic valve replacement (SAVR) upon RV function in patients treated for severe aortic stenosis using CMR. Methods: A 1.5T CMR scan was performed preoperatively and 6 months postoperatively in 112 (56 TAVI, 56 SAVR; 76 ± 8 years) high-risk severe symptomatic aortic stenosis patients across two UK cardiothoracic centres. Results: TAVI patients were older (80.4 ± 6.7 vs. 72.8 ± 7.2 years, p < 0.05) with a higher STS score (2.13 ± 0.73 vs. 5.54 ± 3.41%, p < 0.001). At 6 months, SAVR was associated with a significant increase in RV end systolic volume (33 ± 10 vs. 37 ± 10 ml/m 2, p = 0.008), and decrease in RV ejection fraction (58 ± 8 vs. 53 ± 8%, p = 0.005) and tricuspid annular plane systolic excursion (22 ± 5 vs. 14 ± 3 mm, p < 0.001). Only 4 (7%) SAVR patients had new RV late gadolinium hyper-enhancement with no new cases seen in the TAVI patients at 6 months. Longer surgical cross-clamp time was the only predictor of increased RV end systolic volume at 6 months. Post-TAVI, there was no observed change in RV volumes or function. Over a maximum 6.3 year follow-up, 18(32%) of TAVI patients and 1(1.7%) of SAVR patients had died (p = 0.001). On multivariable Cox analysis, the RV mass at 6 m post-TAVI was independently associated with all-cause mortality (HR 1.359, 95% CI 1.108–1.666, p = 0.003). Conclusions: SAVR results in a deterioration in RV systolic volumes and function associated with longer cross-clamp times and is not fully explained by suboptimal RV protection during cardiopulmonary bypass. TAVI had no adverse impact upon RV volumes or function. … (more)
- Is Part Of:
- International journal of cardiology. Volume 223(2016)
- Journal:
- International journal of cardiology
- Issue:
- Volume 223(2016)
- Issue Display:
- Volume 223, Issue 2016 (2016)
- Year:
- 2016
- Volume:
- 223
- Issue:
- 2016
- Issue Sort Value:
- 2016-0223-2016-0000
- Page Start:
- 639
- Page End:
- 644
- Publication Date:
- 2016-11-15
- Subjects:
- AR aortic regurgitation -- AVA aortic valve area -- CABG coronary artery bypass grafting -- CMR cardiovascular magnetic resonance -- EuroSCORE European System for Cardiac Operative Risk Evaluation -- LGE late gadolinium enhancement -- LVEF left ventricular ejection fraction -- MI myocardial infarction -- MR mitral regurgitation -- NYHA New York Heart Association -- PCI percutaneous coronary intervention -- RVEF right ventricular ejection fraction -- RVESVI right ventricular end systolic volume index -- RVEDVI right ventricular end diastolic volume index -- SAVR surgical aortic valve replacement -- STS Society of Thoracic Surgeons' risk model -- TAVI transcatheter aortic valve implantation
Aortic stenosis -- Transcatheter aortic valve implantation -- Aortic valve replacement -- Right ventricular function -- Cross-clamp time
Cardiology -- Periodicals
Electronic journals
616.12 - Journal URLs:
- http://www.clinicalkey.com/dura/browse/journalIssue/01675273 ↗
http://www.sciencedirect.com/science/journal/01675273 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijcard.2016.08.065 ↗
- Languages:
- English
- ISSNs:
- 0167-5273