Lu, Minxu - Abstract:
- Abstract: Performance of magnesium sacrificial anode under alternating current was investigated in 4 g/L Na2 SO4 simulated backfill solution by weight-loss measurements for 96 h, electrochemical measurements and surface examination. Alternating current increased the dissolution of magnesium, and at the same time, its DC potential shifted positively. The output cathodic protection current decreased at alternating current density of 50 A/m 2 . Polarity reversal occurred to magnesium sacrificial anode as soon as alternating current interference of 100 A/m 2 (or larger) was applied. Besides the "instant effect", the polarity reversal showed a "time effect". It disappeared gradually at alternating current density of 100 A/m 2 . When alternating current density was more than 200 A/m 2, the polarity reversal remained throughout the experiment (96 h). Based on the results of electrochemical measurements and surface examination, mechanism of polarity reversal was proposed. Graphical abstract: Highlights: Mg could not provide enough protection to carbon steel with AC ≥ 100 A/m 2 . Polarity reversal occurred to Mg as soon as AC of 100 A/m 2 (or larger) was applied. The polarity reversal of Mg exhibited a "time effect" under AC. Both AC oscillation and varied polarizations contributed to the polarity reversal of Mg.
- Is Part Of:
- Materials & design. Volume 93(2016)
- Journal:
- Materials & design
- Issue:
- Volume 93(2016)
- Issue Display:
- Volume 93, Issue 2016 (2016)
- Year:
- 2016
- Volume:
- 93
- Issue:
- 2016
- Issue Sort Value:
- 2016-0093-2016-0000
- Page Start:
- 133
- Page End:
- 145
- Publication Date:
- 2016-03-05
- Subjects:
- Magnesium -- Sacrificial anode cathodic protection -- Alternating current -- Polarity reversal -- Instant effect -- Time effect
Materials -- Periodicals
Engineering design -- Periodicals
Matériaux -- Périodiques
Conception technique -- Périodiques
Electronic journals
620.11 - Journal URLs:
- http://catalog.hathitrust.org/api/volumes/oclc/9062775.html ↗
http://www.sciencedirect.com/science/journal/02641275 ↗
http://www.sciencedirect.com/science/journal/02613069 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.matdes.2015.12.112 ↗
- Languages:
- English
- ISSNs:
- 0264-1275
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5393.974000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2437.xml