A histological analysis of human median and ulnar nerves following implantation of Utah slanted electrode arrays. (January 2016)
- Record Type:
- Journal Article
- Title:
- A histological analysis of human median and ulnar nerves following implantation of Utah slanted electrode arrays. (January 2016)
- Main Title:
- A histological analysis of human median and ulnar nerves following implantation of Utah slanted electrode arrays
- Authors:
- Christensen, Michael B.
Wark, Heather A.C.
Hutchinson, Douglas T. - Abstract:
- Abstract: For decades, epineurial electrodes have been used in clinical therapies involving the stimulation of peripheral nerves. However, next generation peripheral nerve interfaces for applications such as neuroprosthetics would benefit from an increased ability to selectively stimulate and record from nerve tissue. This increased selectivity may require the use of more invasive devices, such as the Utah Slanted Electrode Array (USEA). Previous research with USEAs has described the histological response to the implantation of these devices in cats and rats; however, no such data has been presented in humans. Therefore, we describe here the degree of penetration and foreign body reaction to USEAs after a four-week implantation period in human median and ulnar nerves. We found that current array designs penetrate a relatively small percentage of the available endoneurial tissue in these large nerves. When electrode tips were located within the endoneurial tissue, labels for axons and myelin were found in close proximity to electrodes. Consistent with other reports, we found activated macrophages attached to explanted devices, as well as within the tissue surrounding the implantation site. Despite this inflammatory response, devices were able to successfully record single- or multi-unit action potentials and elicit sensory percepts. However, modifying device design to allow for greater nerve penetration, as well as mitigating the inflammatory response to such devices, wouldAbstract: For decades, epineurial electrodes have been used in clinical therapies involving the stimulation of peripheral nerves. However, next generation peripheral nerve interfaces for applications such as neuroprosthetics would benefit from an increased ability to selectively stimulate and record from nerve tissue. This increased selectivity may require the use of more invasive devices, such as the Utah Slanted Electrode Array (USEA). Previous research with USEAs has described the histological response to the implantation of these devices in cats and rats; however, no such data has been presented in humans. Therefore, we describe here the degree of penetration and foreign body reaction to USEAs after a four-week implantation period in human median and ulnar nerves. We found that current array designs penetrate a relatively small percentage of the available endoneurial tissue in these large nerves. When electrode tips were located within the endoneurial tissue, labels for axons and myelin were found in close proximity to electrodes. Consistent with other reports, we found activated macrophages attached to explanted devices, as well as within the tissue surrounding the implantation site. Despite this inflammatory response, devices were able to successfully record single- or multi-unit action potentials and elicit sensory percepts. However, modifying device design to allow for greater nerve penetration, as well as mitigating the inflammatory response to such devices, would likely increase device performance and should be investigated in future research. … (more)
- Is Part Of:
- Biomaterials. Volume 77(2016)
- Journal:
- Biomaterials
- Issue:
- Volume 77(2016)
- Issue Display:
- Volume 77, Issue 2016 (2016)
- Year:
- 2016
- Volume:
- 77
- Issue:
- 2016
- Issue Sort Value:
- 2016-0077-2016-0000
- Page Start:
- 235
- Page End:
- 242
- Publication Date:
- 2016-01
- Subjects:
- Peripheral nerve -- Neural prosthesis -- Foreign body response -- Human -- Microelectrode
Biomedical materials -- Periodicals
Biocompatible Materials -- Periodicals
Biomatériaux -- Périodiques
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01429612 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/01429612 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/01429612 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.biomaterials.2015.11.012 ↗
- Languages:
- English
- ISSNs:
- 0142-9612
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2087.715000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1237.xml