Evaluation of a novel continuous glucose monitoring guided system for adjustment of insulin dosing – PumpTune: a randomized controlled trial. Issue 7 (24th December 2015)
- Record Type:
- Journal Article
- Title:
- Evaluation of a novel continuous glucose monitoring guided system for adjustment of insulin dosing – PumpTune: a randomized controlled trial. Issue 7 (24th December 2015)
- Main Title:
- Evaluation of a novel continuous glucose monitoring guided system for adjustment of insulin dosing – PumpTune: a randomized controlled trial
- Authors:
- Anderson, Donald
Phelan, Helen
Jones, Katie
Smart, Carmel
Oldmeadow, Christopher
King, Bruce
Crock, Patricia - Abstract:
- Abstract : Objective: Retrospective continuous glucose monitoring (CGM) can guide insulin pump adjustments, however, interpretation of data and recommending new pump settings is complex and subjective. We aimed to compare the safety and glycaemic profiles of children after their diabetologist or a novel algorithm (PumpTune) adjusted their insulin pump settings. Research design and methods: In a randomized cross‐over trial of 22 patients aged 6–14 yr with type 1 diabetes with mean Hba1c 7.4% (57 mmol/mol) using CSII, CGM was used over two periods each of 6.5 d to assess percentage time glucose remained within, above and below 3.9–10.0 mmol/L. Before the start of one period pump settings were adjusted by the patient's diabetologist, and before the other insulin pump settings were adjusted by PumpTune. Results: A total of 63.4% of the sensor glucose levels were within target range with PumpTune settings and 57.4% were within range with the clinician settings (p = 0.016). The time spent above target range with PumpTune was 26.9% and with clinician settings was 33.5% (p = 0.021). The time spent below target range with PumpTune was 9.7% and with clinician settings was 9.2% (p = 0.77). The mean number of times when a sensor glucose level <2.75 mmol/L was recorded with PumpTune settings was 2.9 compared with 3.7 with clinician settings (p = 0.39). There were no serious adverse outcomes and no difference in parent‐assessed satisfaction. Conclusions: Automated insulin pump adjustmentAbstract : Objective: Retrospective continuous glucose monitoring (CGM) can guide insulin pump adjustments, however, interpretation of data and recommending new pump settings is complex and subjective. We aimed to compare the safety and glycaemic profiles of children after their diabetologist or a novel algorithm (PumpTune) adjusted their insulin pump settings. Research design and methods: In a randomized cross‐over trial of 22 patients aged 6–14 yr with type 1 diabetes with mean Hba1c 7.4% (57 mmol/mol) using CSII, CGM was used over two periods each of 6.5 d to assess percentage time glucose remained within, above and below 3.9–10.0 mmol/L. Before the start of one period pump settings were adjusted by the patient's diabetologist, and before the other insulin pump settings were adjusted by PumpTune. Results: A total of 63.4% of the sensor glucose levels were within target range with PumpTune settings and 57.4% were within range with the clinician settings (p = 0.016). The time spent above target range with PumpTune was 26.9% and with clinician settings was 33.5% (p = 0.021). The time spent below target range with PumpTune was 9.7% and with clinician settings was 9.2% (p = 0.77). The mean number of times when a sensor glucose level <2.75 mmol/L was recorded with PumpTune settings was 2.9 compared with 3.7 with clinician settings (p = 0.39). There were no serious adverse outcomes and no difference in parent‐assessed satisfaction. Conclusions: Automated insulin pump adjustment with PumpTune is feasible and warrants testing in a larger more varied population over a longer time. In this well‐controlled group of children, PumpTune achieved a more favorable glucose profile. … (more)
- Is Part Of:
- Pediatric diabetes. Volume 17:Issue 7(2016)
- Journal:
- Pediatric diabetes
- Issue:
- Volume 17:Issue 7(2016)
- Issue Display:
- Volume 17, Issue 7 (2016)
- Year:
- 2016
- Volume:
- 17
- Issue:
- 7
- Issue Sort Value:
- 2016-0017-0007-0000
- Page Start:
- 478
- Page End:
- 482
- Publication Date:
- 2015-12-24
- Subjects:
- CSII -- CGM -- PumpTune -- Type 1 diabetes -- Children
Diabetes in children -- Periodicals
616.462 - Journal URLs:
- http://www.blackwellpublishing.com/journal.asp?ref=1399-543X&site=1 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/pedi.12332 ↗
- Languages:
- English
- ISSNs:
- 1399-543X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6417.584000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 615.xml