Carbohydrate‐Deficient Transferrin Determination in a Clinical Setting: Consistency Between Capillary Electrophoresis Assays and Utility of HPLC as a Confirmatory Test. Issue 5 (26th October 2015)
- Record Type:
- Journal Article
- Title:
- Carbohydrate‐Deficient Transferrin Determination in a Clinical Setting: Consistency Between Capillary Electrophoresis Assays and Utility of HPLC as a Confirmatory Test. Issue 5 (26th October 2015)
- Main Title:
- Carbohydrate‐Deficient Transferrin Determination in a Clinical Setting: Consistency Between Capillary Electrophoresis Assays and Utility of HPLC as a Confirmatory Test
- Authors:
- Veronesi, Agnese
Rota, Cristina
Trenti, Tommaso
Cariani, Elisabetta - Abstract:
- Abstract : Background: Carbohydrate‐deficient transferrin (CDT) is used to assess chronic alcohol consumption in administrative and forensic context. The aim of the present study was the optimization of the diagnostic strategy for CDT determination in a clinical laboratory setting. Methods: Two capillary zone electrophoresis (CZE) assays, the CEofix CDT (Analis, Suarlée, Belgium) run on single capillary MDQ instrument and the muticapillary (Sebia, Lisses, France), were compared as screening methods and a commercial high‐performance liquid chromatography (HPLC) assay (Recipe, Munich, Germany) was used for confirmation. Results: In total, 367 serum samples were analyzed by both CZE assays with concordant classification in 92% of cases. All discordant samples were classified as negative by HPLC, as did 2/3 of those that could not be classified by either CZE assay. Classification of samples with CDT values close to cut‐off by CZE was confirmed by HPLC in 95–100% of negative samples but only in 28.6–33.3% of positive samples. Conclusions: Both CZE assays proved suitable for CDT screening. HPLC was useful for discriminating CDT value in most of samples that could not be interpreted by CZE due to analytical interferences. Considering the implication of CDT testing, HPLC assay may also be helpful for the confirmation of positive results close to the cut‐off value of CZE assays.
- Is Part Of:
- Journal of clinical laboratory analysis. Volume 30:Issue 5(2016:Sep.)
- Journal:
- Journal of clinical laboratory analysis
- Issue:
- Volume 30:Issue 5(2016:Sep.)
- Issue Display:
- Volume 30, Issue 5 (2016)
- Year:
- 2016
- Volume:
- 30
- Issue:
- 5
- Issue Sort Value:
- 2016-0030-0005-0000
- Page Start:
- 494
- Page End:
- 499
- Publication Date:
- 2015-10-26
- Subjects:
- carbohydrate deficient transferrin (CDT) -- alcohol -- capillary zone electrophoresis -- HPLC -- cut‐off value -- clinical chemistry
Diagnosis, Laboratory -- Periodicals
Medical laboratory technology -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/jcla.21885 ↗
- Languages:
- English
- ISSNs:
- 0887-8013
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4958.520000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1394.xml