The new neutron grating interferometer at the ANTARES beamline: design, principles and applications. Issue 5 (15th August 2016)
- Record Type:
- Journal Article
- Title:
- The new neutron grating interferometer at the ANTARES beamline: design, principles and applications. Issue 5 (15th August 2016)
- Main Title:
- The new neutron grating interferometer at the ANTARES beamline: design, principles and applications
- Authors:
- Reimann, Tommy
Mühlbauer, Sebastian
Horisberger, Michael
Betz, Benedikt
Böni, Peter
Schulz, Michael - Abstract:
- Abstract : In this paper the principles, design and applications of the new neutron grating interferometry (nGI) setup at the Heinz Maier‐Leibnitz Zentrum are presented. The dark‐field contrast modality of the setup allows one to obtain spatially resolved information about the microstructure of a sample. In this way, nGI closes the gap between neutron imaging and small‐angle neutron scattering. Abstract : Neutron grating interferometry is an advanced method in neutron imaging that allows the simultaneous recording of the transmission, the differential phase and the dark‐field image. The latter in particular has recently been the subject of much interest because of its unique contrast mechanism which marks ultra‐small‐angle neutron scattering within the sample. Hence, in neutron grating interferometry, an imaging contrast is generated by scattering of neutrons off micrometre‐sized inhomogeneities. Although the scatterer cannot be resolved, it leads to a measurable local decoherence of the beam. Here, a report is given on the design considerations, principles and applications of a new neutron grating interferometer which has recently been implemented at the ANTARES beamline at the Heinz Maier‐Leibnitz Zentrum. Its highly flexible design allows users to perform experiments such as directional and quantitative dark‐field imaging which provide spatially resolved information on the anisotropy and shape of the microstructure of the sample. A comprehensive overview of the neutronAbstract : In this paper the principles, design and applications of the new neutron grating interferometry (nGI) setup at the Heinz Maier‐Leibnitz Zentrum are presented. The dark‐field contrast modality of the setup allows one to obtain spatially resolved information about the microstructure of a sample. In this way, nGI closes the gap between neutron imaging and small‐angle neutron scattering. Abstract : Neutron grating interferometry is an advanced method in neutron imaging that allows the simultaneous recording of the transmission, the differential phase and the dark‐field image. The latter in particular has recently been the subject of much interest because of its unique contrast mechanism which marks ultra‐small‐angle neutron scattering within the sample. Hence, in neutron grating interferometry, an imaging contrast is generated by scattering of neutrons off micrometre‐sized inhomogeneities. Although the scatterer cannot be resolved, it leads to a measurable local decoherence of the beam. Here, a report is given on the design considerations, principles and applications of a new neutron grating interferometer which has recently been implemented at the ANTARES beamline at the Heinz Maier‐Leibnitz Zentrum. Its highly flexible design allows users to perform experiments such as directional and quantitative dark‐field imaging which provide spatially resolved information on the anisotropy and shape of the microstructure of the sample. A comprehensive overview of the neutron grating interferometer principle is given, followed by theoretical considerations to optimize the setup performance for different applications. Furthermore, an extensive characterization of the setup is presented and its abilities are demonstrated using selected case studies: (i) dark‐field imaging for material differentiation, (ii) directional dark‐field imaging to mark and quantify micrometre anisotropies within the sample, and (iii) quantitative dark‐field imaging, providing additional size information on the sample's microstructure by probing its autocorrelation function. … (more)
- Is Part Of:
- Journal of applied crystallography. Volume 49:Issue 5(2016)
- Journal:
- Journal of applied crystallography
- Issue:
- Volume 49:Issue 5(2016)
- Issue Display:
- Volume 49, Issue 5 (2016)
- Year:
- 2016
- Volume:
- 49
- Issue:
- 5
- Issue Sort Value:
- 2016-0049-0005-0000
- Page Start:
- 1488
- Page End:
- 1500
- Publication Date:
- 2016-08-15
- Subjects:
- neutron radiography -- neutron imaging -- neutron grating interferometry -- neutron dark‐field imaging -- small‐angle neutron scattering -- ultra‐small‐angle neutron scattering
Crystallography -- Periodicals
548.05 - Journal URLs:
- http://firstsearch.oclc.org ↗
http://journals.iucr.org/j/journalhomepage.html ↗
http://www-us.ebsco.com/online/direct.asp?JournalID=105188 ↗
http://www.blackwell-synergy.com/loi/jcr ↗
http://www.blackwell-synergy.com/servlet/useragent?func=showIssues&code=jcr&open=2004#C2004 ↗
http://onlinelibrary.wiley.com/journal/10.1107/S16005767 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1107/S1600576716011080 ↗
- Languages:
- English
- ISSNs:
- 0021-8898
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4942.400000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 2066.xml