Using thermal desorption electrospray ionization mass spectrometry to rapidly determine antimicrobial preservatives in cosmetics. (22nd September 2016)
- Record Type:
- Journal Article
- Title:
- Using thermal desorption electrospray ionization mass spectrometry to rapidly determine antimicrobial preservatives in cosmetics. (22nd September 2016)
- Main Title:
- Using thermal desorption electrospray ionization mass spectrometry to rapidly determine antimicrobial preservatives in cosmetics
- Authors:
- Cho, Yi‐Tzu
Su, Hung
Lin, Shiang‐Jiun
Wu, Ban‐Hsin
Lai, Ching‐Yu
Huang, I‐Ching - Abstract:
- Abstract : Rationale: Characterization and quantification of permitted preservatives are important inspections to prevent the overuse of preservatives in authentic formulations. However, the complexity of sample matrices makes preservative determination in cosmetics a tedious process. A rapid analytical strategy to identify preservatives would insure large numbers of products are in compliance with government regulations. Methods: Thermal desorption electrospray ionization mass spectrometry (TD‐ESI‐MS) was used to directly detect preservative compounds in authentic formulations without sample pretreatment. The technique employs a metal probe, which was configured for sampling cosmetics in their original states and was inserted in a closed preheated oven to thermally desorb analytes. The desorbed analytes were then carried by a nitrogen gas stream into an ESI plume, where the formed ions were subsequently detected by the mass analyzer. Results: The TD‐ESI mass and tandem mass spectra of different classes of preservative standards were rapidly obtained, and the limits of detection were far below the legal limit of their respective concentrations. The preservatives were also directly detected in different types of authentic formulations in the absence of sample preparation, and within a few seconds per sample. Calibration curves for preservatives in four common formulations yielded good linearity in the regulation‐allowed range. Conclusions: Due to its sensitivity, shortAbstract : Rationale: Characterization and quantification of permitted preservatives are important inspections to prevent the overuse of preservatives in authentic formulations. However, the complexity of sample matrices makes preservative determination in cosmetics a tedious process. A rapid analytical strategy to identify preservatives would insure large numbers of products are in compliance with government regulations. Methods: Thermal desorption electrospray ionization mass spectrometry (TD‐ESI‐MS) was used to directly detect preservative compounds in authentic formulations without sample pretreatment. The technique employs a metal probe, which was configured for sampling cosmetics in their original states and was inserted in a closed preheated oven to thermally desorb analytes. The desorbed analytes were then carried by a nitrogen gas stream into an ESI plume, where the formed ions were subsequently detected by the mass analyzer. Results: The TD‐ESI mass and tandem mass spectra of different classes of preservative standards were rapidly obtained, and the limits of detection were far below the legal limit of their respective concentrations. The preservatives were also directly detected in different types of authentic formulations in the absence of sample preparation, and within a few seconds per sample. Calibration curves for preservatives in four common formulations yielded good linearity in the regulation‐allowed range. Conclusions: Due to its sensitivity, short analysis time, repeatability, and quantitative ability, TD‐ESI‐MS may serve as a suitable tool for large‐scale screening of cosmetic preservatives to assure product safety. Copyright © 2016 John Wiley & Sons, Ltd. … (more)
- Is Part Of:
- Rapid communications in mass spectrometry. Volume 30:Number 21(2016)
- Journal:
- Rapid communications in mass spectrometry
- Issue:
- Volume 30:Number 21(2016)
- Issue Display:
- Volume 30, Issue 21 (2016)
- Year:
- 2016
- Volume:
- 30
- Issue:
- 21
- Issue Sort Value:
- 2016-0030-0021-0000
- Page Start:
- 2315
- Page End:
- 2322
- Publication Date:
- 2016-09-22
- Subjects:
- Mass spectrometry -- Periodicals
543.65 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/rcm.7706 ↗
- Languages:
- English
- ISSNs:
- 0951-4198
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7254.440000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 1023.xml