Transducer‐based evaluation of tremor. Issue 9 (6th June 2016)
- Record Type:
- Journal Article
- Title:
- Transducer‐based evaluation of tremor. Issue 9 (6th June 2016)
- Main Title:
- Transducer‐based evaluation of tremor
- Authors:
- Haubenberger, Dietrich
Abbruzzese, Giovanni
Bain, Peter G.
Bajaj, Nin
Benito‐León, Julián
Bhatia, Kailash P.
Deuschl, Günther
Forjaz, Maria João
Hallett, Mark
Louis, Elan D.
Lyons, Kelly E.
Mestre, Tiago A.
Raethjen, Jan
Stamelou, Maria
Tan, Eng‐King
Testa, Claudia M.
Elble, Rodger J. - Other Names:
- Sánchez‐Ferro Álvaro guestEditor.
Maetzler Walter guestEditor. - Abstract:
- ABSTRACT: The International Parkinson and Movement Disorder Society established a task force on tremor that reviewed the use of transducer‐based measures in the quantification and characterization of tremor. Studies of accelerometry, electromyography, activity monitoring, gyroscopy, digitizing tablet‐based measures, vocal acoustic analysis, and several other transducer‐based methods were identified by searchingPubMed.gov . The availability, use, acceptability, reliability, validity, and responsiveness were reviewed for each measure using the following criteria: (1) used in the assessment of tremor; (2) used in published studies by people other than the developers; and (3) adequate clinimetric testing. Accelerometry, gyroscopy, electromyography, and digitizing tablet‐based measures fulfilled all three criteria. Compared to rating scales, transducers are far more sensitive to changes in tremor amplitude and frequency, but they do not appear to be more capable of detecting a change that exceeds random variability in tremor amplitude (minimum detectable change). The use of transducer‐based measures requires careful attention to their limitations and validity in a particular clinical or research setting. © 2016 International Parkinson and Movement Disorder Society
- Is Part Of:
- Movement disorders. Volume 31:Issue 9(2016)
- Journal:
- Movement disorders
- Issue:
- Volume 31:Issue 9(2016)
- Issue Display:
- Volume 31, Issue 9 (2016)
- Year:
- 2016
- Volume:
- 31
- Issue:
- 9
- Issue Sort Value:
- 2016-0031-0009-0000
- Page Start:
- 1327
- Page End:
- 1336
- Publication Date:
- 2016-06-06
- Subjects:
- tremor -- transducers -- accelerometry -- electromyography -- reproducibility of results
Movement disorders -- Periodicals
610 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1531-8257 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mds.26671 ↗
- Languages:
- English
- ISSNs:
- 0885-3185
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5980.317200
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2472.xml