Cochlear implantation in recipients with single-sided deafness: Audiological performance. (3rd July 2016)
- Record Type:
- Journal Article
- Title:
- Cochlear implantation in recipients with single-sided deafness: Audiological performance. (3rd July 2016)
- Main Title:
- Cochlear implantation in recipients with single-sided deafness: Audiological performance
- Authors:
- Hoth, Sebastian
Rösli-Khabas, Maria
Herisanu, Ioana
Plinkert, Peter K.
Praetorius, Mark - Abstract:
- Abstract : Objective : To examine the auditory benefit of cochlear implants (CI) in patients with single-sided deafness (SSD). Material and methods : Twenty patients with a normal pure tone audiogram ( n = 8) or moderate hearing loss ( n = 12) in one ear and a CI system MED-EL SONATA/CONCERTO + OPUS2 ( n = 12), COCHLEAR CI24RE(ST) + CP810 ( n = 7) and Advanced Bionics HiRes90 K + Harmony ( n = 1) in the contralateral ear and with at least 6 months of CI experience were tested with respect to directional hearing, speech perception in noise, binaural loudness matching, and binaural pitch matching. Twenty-six normal hearing controls were included for normative reference. Results : Addition of the CI significantly improves directional hearing (percentage of correct source identifications improved from 14.9 to 15.6%, root mean square error decreased from 125 to 93°) and improves speech perception in noise (speech perception threshold median improved from −2.3 to −6.0 dB signal to noise ratio, equivalent to a binaural intelligibility level difference = 3.7 dB). Alternate binaural loudness balancing showed that matching takes place at levels between 48 and 55 dB HL (group averages). In the pitch matching experiment, the standard deviation of the relative interaural frequency difference at 500, 1000, and 2000 Hz was 24.5, 22.8, and 24.0%, respectively (compared to 11.7, 14.4, and 12.3% in the control group). Conclusions : In SSD, cochlear implantation considerably improvesAbstract : Objective : To examine the auditory benefit of cochlear implants (CI) in patients with single-sided deafness (SSD). Material and methods : Twenty patients with a normal pure tone audiogram ( n = 8) or moderate hearing loss ( n = 12) in one ear and a CI system MED-EL SONATA/CONCERTO + OPUS2 ( n = 12), COCHLEAR CI24RE(ST) + CP810 ( n = 7) and Advanced Bionics HiRes90 K + Harmony ( n = 1) in the contralateral ear and with at least 6 months of CI experience were tested with respect to directional hearing, speech perception in noise, binaural loudness matching, and binaural pitch matching. Twenty-six normal hearing controls were included for normative reference. Results : Addition of the CI significantly improves directional hearing (percentage of correct source identifications improved from 14.9 to 15.6%, root mean square error decreased from 125 to 93°) and improves speech perception in noise (speech perception threshold median improved from −2.3 to −6.0 dB signal to noise ratio, equivalent to a binaural intelligibility level difference = 3.7 dB). Alternate binaural loudness balancing showed that matching takes place at levels between 48 and 55 dB HL (group averages). In the pitch matching experiment, the standard deviation of the relative interaural frequency difference at 500, 1000, and 2000 Hz was 24.5, 22.8, and 24.0%, respectively (compared to 11.7, 14.4, and 12.3% in the control group). Conclusions : In SSD, cochlear implantation considerably improves audiological performance in terms of directional hearing, binaural signal equivalence, and speech perception. … (more)
- Is Part Of:
- Cochlear implants international. Volume 17:Number 4(2016)
- Journal:
- Cochlear implants international
- Issue:
- Volume 17:Number 4(2016)
- Issue Display:
- Volume 17, Issue 4 (2016)
- Year:
- 2016
- Volume:
- 17
- Issue:
- 4
- Issue Sort Value:
- 2016-0017-0004-0000
- Page Start:
- 190
- Page End:
- 199
- Publication Date:
- 2016-07-03
- Subjects:
- Cochlear implant -- Single-sided deafness -- SSD -- Unilateral hearing loss -- UHL -- Binaural matching -- Speech perception -- Directional hearing
Cochlear implants -- Periodicals
617.882 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1556-9152 ↗
http://www.ingenta.com/journals/browse/whurr/cii ↗
http://www.ingentaconnect.com/content/maney/cii ↗
http://www.tandfonline.com/loi/ycii20 ↗
http://maneypublishing.com/ ↗ - DOI:
- 10.1080/14670100.2016.1176778 ↗
- Languages:
- English
- ISSNs:
- 1467-0100
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3292.724200
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1124.xml