Loss of bottlebrush stiffness due to free polymers. Issue 38 (7th September 2016)
- Record Type:
- Journal Article
- Title:
- Loss of bottlebrush stiffness due to free polymers. Issue 38 (7th September 2016)
- Main Title:
- Loss of bottlebrush stiffness due to free polymers
- Authors:
- Storm, Ingeborg M.
Kornreich, Micha
Voets, Ilja K.
Beck, Roy
de Vries, Renko
Cohen Stuart, Martien A.
Leermakers, Frans A. M. - Abstract:
- Abstract : Increasing free polymer conc. inhibits liquid crystalline ordering of supramolecular bottlebrushes due to a loss in the stretching of the side chains. Abstract : A recently introduced DNA-bottlebrush system, which is formed by the co-assembly of DNA with a genetically engineered cationic polymer-like protein, is subjected to osmotic stress conditions. We measured the inter-DNA distances by X-ray scattering. Our co-assembled DNA-bottlebrush system is one of the few bottlebrushes known to date that shows liquid crystalline behaviour. The alignment of the DNA bottlebrushes was expected to increase with imposed pressure, but interestingly this did not always happen. Molecularly detailed self-consistent field calculations targeted to complement the experiments, focused on the role of molecular crowding on the induced persistence length l p due to the side chains and the cross-sectional width D of the molecular bottlebrushes. Both the thickness as well as the backbone persistence length drop with increasing protein–polymer bulk concentrations and dramatic effects are found above the overlap threshold. The flexibilisation is more significant and therefore the bottlebrush aspect ratio, l p / D, decreases with protein–polymer concentration. This loss in aspect ratio is yet another argument why molecular bottlebrushes rarely order in anisotropic phases and may explain why bottlebrushes are excellent lubricants.
- Is Part Of:
- Soft matter. Volume 12:Issue 38(2016)
- Journal:
- Soft matter
- Issue:
- Volume 12:Issue 38(2016)
- Issue Display:
- Volume 12, Issue 38 (2016)
- Year:
- 2016
- Volume:
- 12
- Issue:
- 38
- Issue Sort Value:
- 2016-0012-0038-0000
- Page Start:
- 8004
- Page End:
- 8014
- Publication Date:
- 2016-09-07
- Subjects:
- Soft condensed matter -- Periodicals
530.413 - Journal URLs:
- http://www.rsc.org/Publishing/Journals/sm/index.asp ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c6sm01227b ↗
- Languages:
- English
- ISSNs:
- 1744-683X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8321.419000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 1424.xml