"Anterior subcutaneous pelvic internal fixator (INFIX), Is it safe?" A cadaveric study. Issue 10 (October 2016)
- Record Type:
- Journal Article
- Title:
- "Anterior subcutaneous pelvic internal fixator (INFIX), Is it safe?" A cadaveric study. Issue 10 (October 2016)
- Main Title:
- "Anterior subcutaneous pelvic internal fixator (INFIX), Is it safe?" A cadaveric study
- Authors:
- Apivatthakakul, T.
Rujiwattanapong, N. - Abstract:
- Abstract: Introduction: Anterior pelvic internal fixator (INFIX) is used to treat unstable pelvic ring injuries. Nerve injury complications with this procedure have been reported. Objectives: This anatomic study attempted to identify structures at risk after application of INFIX. Materials and methods: INFIX was applied in fifteen fresh, frozen, anatomical specimens using polyaxial pedicular screws and subcutaneous rods. Surgical dissection was done to identify the structures at risk including the femoral nerve (FN), femoral artery (FA), femoral vein (FV) and the lateral femoral cutaneous nerve (LFCN) related to which are potentially affected by the implant. Results: All structures at risk were closer to the rod than to the pedicular screw. Measurements were made between the rod and the structures at risk. The LFCN was an average of 13.49 ± 1.65 mm (95% CI 12.871–14.103) from the lateral end of the rod. The FN was an average of 12.43 ± 3.42 mm (95% CI 11.151–13.709), the FA was an average of 12.80 ± 3.67 (95% CI 11.430–14.173) and the FV was an average of 13.48 ± 3.73 (95% CI 12.082–14.871) below the rod. No direct compression of the rod to the structure at risk was observed. Conclusions: The femoral nerve is the structure most at risk of compression by the INFIX rod. Careful surgical technique is required in every step of this surgery. We suggest using polyaxial screws and recommend that during screw insertion the surgeon should leave some space between the screw and rectusAbstract: Introduction: Anterior pelvic internal fixator (INFIX) is used to treat unstable pelvic ring injuries. Nerve injury complications with this procedure have been reported. Objectives: This anatomic study attempted to identify structures at risk after application of INFIX. Materials and methods: INFIX was applied in fifteen fresh, frozen, anatomical specimens using polyaxial pedicular screws and subcutaneous rods. Surgical dissection was done to identify the structures at risk including the femoral nerve (FN), femoral artery (FA), femoral vein (FV) and the lateral femoral cutaneous nerve (LFCN) related to which are potentially affected by the implant. Results: All structures at risk were closer to the rod than to the pedicular screw. Measurements were made between the rod and the structures at risk. The LFCN was an average of 13.49 ± 1.65 mm (95% CI 12.871–14.103) from the lateral end of the rod. The FN was an average of 12.43 ± 3.42 mm (95% CI 11.151–13.709), the FA was an average of 12.80 ± 3.67 (95% CI 11.430–14.173) and the FV was an average of 13.48 ± 3.73 (95% CI 12.082–14.871) below the rod. No direct compression of the rod to the structure at risk was observed. Conclusions: The femoral nerve is the structure most at risk of compression by the INFIX rod. Careful surgical technique is required in every step of this surgery. We suggest using polyaxial screws and recommend that during screw insertion the surgeon should leave some space between the screw and rectus fascia. The the rod should be trimmed as short as possible to reduce LFCN irritation. … (more)
- Is Part Of:
- Injury. Volume 47:Issue 10(2016)
- Journal:
- Injury
- Issue:
- Volume 47:Issue 10(2016)
- Issue Display:
- Volume 47, Issue 10 (2016)
- Year:
- 2016
- Volume:
- 47
- Issue:
- 10
- Issue Sort Value:
- 2016-0047-0010-0000
- Page Start:
- 2077
- Page End:
- 2080
- Publication Date:
- 2016-10
- Subjects:
- Anterior pelvic internal fixation -- INFIX -- Femoral nerve -- Lateral femoral cutaneous nerve -- Injury
Wounds and injuries -- Surgery -- Periodicals
Accidents -- Periodicals
Wounds and Injuries -- surgery -- Periodicals
Lésions et blessures -- Chirurgie -- Périodiques
Electronic journals
Electronic journals
617.1 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00201383 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/00201383 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00201383 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.injury.2016.08.006 ↗
- Languages:
- English
- ISSNs:
- 0020-1383
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4514.400000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 296.xml