Changes in the syndesmotic reduction after syndesmotic screw fixation for ankle malleolar fractures: One-year longitudinal evaluations using computer tomography. Issue 10 (October 2016)
- Record Type:
- Journal Article
- Title:
- Changes in the syndesmotic reduction after syndesmotic screw fixation for ankle malleolar fractures: One-year longitudinal evaluations using computer tomography. Issue 10 (October 2016)
- Main Title:
- Changes in the syndesmotic reduction after syndesmotic screw fixation for ankle malleolar fractures: One-year longitudinal evaluations using computer tomography
- Authors:
- Endo, Jun
Yamaguchi, Satoshi
Saito, Masahiko
Morikawa, Tsuguo
Akagi, Ryuichiro
Sasho, Takahisa - Abstract:
- Abstract: Introduction: To evaluate time-dependent changes in the syndesmotic reduction after syndesmotic screw fixation and one year after screw removal for ankle malleolar fractures, and to assess whether the incidence of syndesmotic malreduction changes depending on the measurement method. Methods: We assessed twenty patients who underwent syndesmotic screw fixation for ankle fractures. The syndesmotic screws were removed after six weeks of the fracture surgery. Syndesmotic reduction was assessed within two weeks of the fracture surgery and one year after the screw removal using the axial computer tomographic images. Side-to-side differences in the anterior and posterior tibiofibular distances, anteroposterior fibular translation, and fibular rotation were measured. Results: The mean anterior tibiofibular distance was 0.7 mm after syndesmotic fixation. It increased to 1.9 mm at one year after screw removal ( p = 0.002). After syndesmotic fixation, four ankles had malreduction of the anterior tibiofibular distance, including three ankles with widening and one with overtightening. At one year, eight ankles had malreduction, all of whom had widening. The other measurement values did not change over time (0.1 mm vs. 0.6 mm for the posterior tibiofibular distance, 0.2 mm vs. 0.3 mm for the anteroposterior fibular translation, and 0.7 ° vs. 0 ° for the fibular rotation). The incidences of malreduction were significantly different depending on the definition of malreduction,Abstract: Introduction: To evaluate time-dependent changes in the syndesmotic reduction after syndesmotic screw fixation and one year after screw removal for ankle malleolar fractures, and to assess whether the incidence of syndesmotic malreduction changes depending on the measurement method. Methods: We assessed twenty patients who underwent syndesmotic screw fixation for ankle fractures. The syndesmotic screws were removed after six weeks of the fracture surgery. Syndesmotic reduction was assessed within two weeks of the fracture surgery and one year after the screw removal using the axial computer tomographic images. Side-to-side differences in the anterior and posterior tibiofibular distances, anteroposterior fibular translation, and fibular rotation were measured. Results: The mean anterior tibiofibular distance was 0.7 mm after syndesmotic fixation. It increased to 1.9 mm at one year after screw removal ( p = 0.002). After syndesmotic fixation, four ankles had malreduction of the anterior tibiofibular distance, including three ankles with widening and one with overtightening. At one year, eight ankles had malreduction, all of whom had widening. The other measurement values did not change over time (0.1 mm vs. 0.6 mm for the posterior tibiofibular distance, 0.2 mm vs. 0.3 mm for the anteroposterior fibular translation, and 0.7 ° vs. 0 ° for the fibular rotation). The incidences of malreduction were significantly different depending on the definition of malreduction, ranging from 10% to 50% after syndesmotic fixation ( p = 0.01) and from 20% to 60% at one year after screw removal ( p = 0.02). Conclusions: The anterior tibiofibular distance widened after one year of syndesmotic screw removal. The incidence of malreduction varied depending on the measurement method. … (more)
- Is Part Of:
- Injury. Volume 47:Issue 10(2016)
- Journal:
- Injury
- Issue:
- Volume 47:Issue 10(2016)
- Issue Display:
- Volume 47, Issue 10 (2016)
- Year:
- 2016
- Volume:
- 47
- Issue:
- 10
- Issue Sort Value:
- 2016-0047-0010-0000
- Page Start:
- 2360
- Page End:
- 2365
- Publication Date:
- 2016-10
- Subjects:
- Syndesmotic reduction -- Syndesmotic screw fixation -- Ankle malleolar fracture -- Computer tomography
Wounds and injuries -- Surgery -- Periodicals
Accidents -- Periodicals
Wounds and Injuries -- surgery -- Periodicals
Lésions et blessures -- Chirurgie -- Périodiques
Electronic journals
Electronic journals
617.1 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00201383 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/00201383 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00201383 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.injury.2016.07.031 ↗
- Languages:
- English
- ISSNs:
- 0020-1383
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4514.400000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 296.xml