Left Ventricular Rotational Mechanics in Children After Heart Transplantation. (September 2016)
- Record Type:
- Journal Article
- Title:
- Left Ventricular Rotational Mechanics in Children After Heart Transplantation. (September 2016)
- Main Title:
- Left Ventricular Rotational Mechanics in Children After Heart Transplantation
- Authors:
- Nawaytou, Hythem M.
Yubbu, Putri
Montero, Andrea E.
Nandi, Deipanjan
O'Connor, Matthew J.
Shaddy, Robert E.
Banerjee, Anirban - Abstract:
- Abstract : Background—: Left ventricular (LV) dysfunction after orthotopic heart transplantation (OHT) is multifactorial and can be an indicator of graft rejection or coronary artery vasculopathy. Analysis of rotational mechanics may help in the early diagnosis of ventricular dysfunction. Studies describing the left ventricular rotational strain in children after OHT are lacking. It is important to establish the baseline rotational mechanics in pediatric OHT to pursue further studies in this population. Methods and Results—: Rotational strain measured by speckle tracking was compared in 32 children after OHT, with no evidence of active rejection or coronary artery vasculopathy with 35 age-matched normal controls. Twelve OHT patients and 13 controls underwent moderate exercise with pre- and postexercise echocardiography. Torsion, slope of the systolic limb of the torsion–radial displacement loop, and the untwist rate were significantly higher in OHT patients (torsion: median 2.7°/cm [Q1–Q3, 2.3–3.2] versus 2.3°/cm [Q1–Q3, 1.9–2.7]; P =0.03, torsion–radial displacement loop: 2.7°/mm [Q1–Q3, 2.1–3.6] versus 2.0°/mm [Q1–Q3, 1.6–2.7]; P =0.008, indexed peak untwist rate: −21.6°/s/cm [Q1–Q3, −24.3 to −15.7] versus −17.1°/s/cm [Q1–Q3, −19.6 to −13.3]; P =0.01). Contrary to controls, OHT recipients were unable to increase torsion with exercise (OHT: 2.8°/cm [2.7–3.2] versus 3°/cm [2.4–3.5]; P =0.81, controls: 2.2°/cm [2–2.6] versus 3°/cm [2.4–3.7]; P =0.01, pre and post exercise,Abstract : Background—: Left ventricular (LV) dysfunction after orthotopic heart transplantation (OHT) is multifactorial and can be an indicator of graft rejection or coronary artery vasculopathy. Analysis of rotational mechanics may help in the early diagnosis of ventricular dysfunction. Studies describing the left ventricular rotational strain in children after OHT are lacking. It is important to establish the baseline rotational mechanics in pediatric OHT to pursue further studies in this population. Methods and Results—: Rotational strain measured by speckle tracking was compared in 32 children after OHT, with no evidence of active rejection or coronary artery vasculopathy with 35 age-matched normal controls. Twelve OHT patients and 13 controls underwent moderate exercise with pre- and postexercise echocardiography. Torsion, slope of the systolic limb of the torsion–radial displacement loop, and the untwist rate were significantly higher in OHT patients (torsion: median 2.7°/cm [Q1–Q3, 2.3–3.2] versus 2.3°/cm [Q1–Q3, 1.9–2.7]; P =0.03, torsion–radial displacement loop: 2.7°/mm [Q1–Q3, 2.1–3.6] versus 2.0°/mm [Q1–Q3, 1.6–2.7]; P =0.008, indexed peak untwist rate: −21.6°/s/cm [Q1–Q3, −24.3 to −15.7] versus −17.1°/s/cm [Q1–Q3, −19.6 to −13.3]; P =0.01). Contrary to controls, OHT recipients were unable to increase torsion with exercise (OHT: 2.8°/cm [2.7–3.2] versus 3°/cm [2.4–3.5]; P =0.81, controls: 2.2°/cm [2–2.6] versus 3°/cm [2.4–3.7]; P =0.01, pre and post exercise, respectively). The systolic slope of the torsion–radial displacement loop relationship decreased with exercise in most OHT patients. Conclusions—: Baseline rotational strain in OHT patients is higher than normal with a blunted response to exercise. The slope of torsion–radial displacement loop, and its response to exercise, may serve as a marker of left ventricular dysfunction in OHT patients. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Circulation. Volume 9:Number 9(2016)
- Journal:
- Circulation
- Issue:
- Volume 9:Number 9(2016)
- Issue Display:
- Volume 9, Issue 9 (2016)
- Year:
- 2016
- Volume:
- 9
- Issue:
- 9
- Issue Sort Value:
- 2016-0009-0009-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-09
- Subjects:
- hemodynamics -- mechanics -- pediatrics -- torsion -- transplantation
Cardiovascular system -- Imaging -- Periodicals
Heart -- Imaging -- Periodicals
616.1075405 - Journal URLs:
- http://circimaging.ahajournals.org/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1161/CIRCIMAGING.116.004848 ↗
- Languages:
- English
- ISSNs:
- 1941-9651
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3265.262750
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 60.xml