Comparison of Perfusion CT Software to Predict the Final Infarct Volume After Thrombectomy. Issue 9 (September 2016)
- Record Type:
- Journal Article
- Title:
- Comparison of Perfusion CT Software to Predict the Final Infarct Volume After Thrombectomy. Issue 9 (September 2016)
- Main Title:
- Comparison of Perfusion CT Software to Predict the Final Infarct Volume After Thrombectomy
- Authors:
- Austein, Friederike
Riedel, Christian
Kerby, Tina
Meyne, Johannes
Binder, Andreas
Lindner, Thomas
Huhndorf, Monika
Wodarg, Fritz
Jansen, Olav - Abstract:
- Abstract : Background and Purpose—: Computed tomographic perfusion represents an interesting physiological imaging modality to select patients for reperfusion therapy in acute ischemic stroke. The purpose of our study was to determine the accuracy of different commercial perfusion CT software packages (Philips (A), Siemens (B), and RAPID (C)) to predict the final infarct volume (FIV) after mechanical thrombectomy. Methods—: Single-institutional computed tomographic perfusion data from 147 mechanically recanalized acute ischemic stroke patients were postprocessed. Ischemic core and FIV were compared about thrombolysis in cerebral infarction (TICI) score and time interval to reperfusion. FIV was measured at follow-up imaging between days 1 and 8 after stroke. Results—: In 118 successfully recanalized patients (TICI 2b/3), a moderately to strongly positive correlation was observed between ischemic core and FIV. The highest accuracy and best correlation are shown in early and fully recanalized patients (Pearson r for A=0.42, B=0.64, and C=0.83; P <0.001). Bland–Altman plots and boxplots demonstrate smaller ranges in package C than in A and B. Significant differences were found between the packages about over- and underestimation of the ischemic core. Package A, compared with B and C, estimated more than twice as many patients with a malignant stroke profile ( P <0.001). Package C best predicted hypoperfusion volume in nonsuccessfully recanalized patients. Conclusions—: Our studyAbstract : Background and Purpose—: Computed tomographic perfusion represents an interesting physiological imaging modality to select patients for reperfusion therapy in acute ischemic stroke. The purpose of our study was to determine the accuracy of different commercial perfusion CT software packages (Philips (A), Siemens (B), and RAPID (C)) to predict the final infarct volume (FIV) after mechanical thrombectomy. Methods—: Single-institutional computed tomographic perfusion data from 147 mechanically recanalized acute ischemic stroke patients were postprocessed. Ischemic core and FIV were compared about thrombolysis in cerebral infarction (TICI) score and time interval to reperfusion. FIV was measured at follow-up imaging between days 1 and 8 after stroke. Results—: In 118 successfully recanalized patients (TICI 2b/3), a moderately to strongly positive correlation was observed between ischemic core and FIV. The highest accuracy and best correlation are shown in early and fully recanalized patients (Pearson r for A=0.42, B=0.64, and C=0.83; P <0.001). Bland–Altman plots and boxplots demonstrate smaller ranges in package C than in A and B. Significant differences were found between the packages about over- and underestimation of the ischemic core. Package A, compared with B and C, estimated more than twice as many patients with a malignant stroke profile ( P <0.001). Package C best predicted hypoperfusion volume in nonsuccessfully recanalized patients. Conclusions—: Our study demonstrates best accuracy and approximation between the results of a fully automated software (RAPID) and FIV, especially in early and fully recanalized patients. Furthermore, this software package overestimated the FIV to a significantly lower degree and estimated a malignant mismatch profile less often than other software. Abstract : Supplemental Digital Content is available in the text. … (more)
- Is Part Of:
- Stroke. Volume 47:Issue 9(2016)
- Journal:
- Stroke
- Issue:
- Volume 47:Issue 9(2016)
- Issue Display:
- Volume 47, Issue 9 (2016)
- Year:
- 2016
- Volume:
- 47
- Issue:
- 9
- Issue Sort Value:
- 2016-0047-0009-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-09
- Subjects:
- perfusion imaging -- reperfusion -- software -- stroke -- thrombectomy
Cerebrovascular disease -- Periodicals
Cerebral circulation -- Periodicals
616.81 - Journal URLs:
- http://ovidsp.tx.ovid.com/sp-3.16.0b/ovidweb.cgi?&S=GJCMFPNHCPDDNANKNCKKCFFBNGMHAA00&Browse=Toc+Children%7cYES%7cS.sh.15204_1441956414_76.15204_1441956414_88.15204_1441956414_96%7c411%7c50 ↗
http://www.stroke.ahajournals.org/ ↗
http://stroke.ahajournals.org/ ↗
http://journals.lww.com ↗
http://www.lww.com/Product/0039-2499 ↗ - DOI:
- 10.1161/STROKEAHA.116.013147 ↗
- Languages:
- English
- ISSNs:
- 0039-2499
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8474.900000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 574.xml