Dicationic polymeric ionic‐liquid‐based magnetic material as an adsorbent for the magnetic solid‐phase extraction of organophosphate pesticides and polycyclic aromatic hydrocarbons. Issue 16 (1st August 2016)
- Record Type:
- Journal Article
- Title:
- Dicationic polymeric ionic‐liquid‐based magnetic material as an adsorbent for the magnetic solid‐phase extraction of organophosphate pesticides and polycyclic aromatic hydrocarbons. Issue 16 (1st August 2016)
- Main Title:
- Dicationic polymeric ionic‐liquid‐based magnetic material as an adsorbent for the magnetic solid‐phase extraction of organophosphate pesticides and polycyclic aromatic hydrocarbons
- Authors:
- Jiang, Qiong
Liu, Qin
Chen, Qiliang
Zhao, Wenjie
Xiang, Guoqiang
He, Lijun
Jiang, Xiuming
Zhang, Shusheng - Abstract:
- Abstract : Magnetic particles modified with a dicationic polymeric ionic liquid are described as a new adsorbent in magnetic solid‐phase extraction. They were obtained through the copolymerization of a 1, 8‐di(3‐vinylimidazolium)octane‐based ionic liquid with vinyl‐modified SiO2 @Fe3 O4, and were characterized by FTIR spectroscopy, X‐ray diffraction, and vibrating sample magnetometry. The modified magnetic particles are effective in the extraction of organophosphate pesticides and polycyclic aromatic hydrocarbons. Also, they can provide different extraction performance for the selected analytes including fenitrothion, parathion, fenthion, phoxim, phenanthrene, and fluoranthene, where the extraction efficiency is found to be in agreement with the hydrophobicity of analytes. Various factors influencing the extraction efficiency, such as, the amount of adsorbent, extraction, and desorption time, and type and volume of the desorption solvent, were optimized. Under the optimized conditions, a good linearity ranging from 1–100 μg/L is obtained for all analytes, except for parathion (2–200 μg/L), where the correlation coefficients varied from 0.9960 to 0.9998. The limits of detection are 0.2–0.8 μg/L, and intraday and interday relative standard deviations are 1.7–7.4% ( n = 5) and 3.8–8.0% ( n = 3), respectively. The magnetic solid‐phase extraction combined with high‐performance liquid chromatography can be applied for the detection of trace targets in real water samples withAbstract : Magnetic particles modified with a dicationic polymeric ionic liquid are described as a new adsorbent in magnetic solid‐phase extraction. They were obtained through the copolymerization of a 1, 8‐di(3‐vinylimidazolium)octane‐based ionic liquid with vinyl‐modified SiO2 @Fe3 O4, and were characterized by FTIR spectroscopy, X‐ray diffraction, and vibrating sample magnetometry. The modified magnetic particles are effective in the extraction of organophosphate pesticides and polycyclic aromatic hydrocarbons. Also, they can provide different extraction performance for the selected analytes including fenitrothion, parathion, fenthion, phoxim, phenanthrene, and fluoranthene, where the extraction efficiency is found to be in agreement with the hydrophobicity of analytes. Various factors influencing the extraction efficiency, such as, the amount of adsorbent, extraction, and desorption time, and type and volume of the desorption solvent, were optimized. Under the optimized conditions, a good linearity ranging from 1–100 μg/L is obtained for all analytes, except for parathion (2–200 μg/L), where the correlation coefficients varied from 0.9960 to 0.9998. The limits of detection are 0.2–0.8 μg/L, and intraday and interday relative standard deviations are 1.7–7.4% ( n = 5) and 3.8–8.0% ( n = 3), respectively. The magnetic solid‐phase extraction combined with high‐performance liquid chromatography can be applied for the detection of trace targets in real water samples with satisfactory relative recoveries and relative standard deviations. … (more)
- Is Part Of:
- Journal of separation science. Volume 39:Issue 16(2016)
- Journal:
- Journal of separation science
- Issue:
- Volume 39:Issue 16(2016)
- Issue Display:
- Volume 39, Issue 16 (2016)
- Year:
- 2016
- Volume:
- 39
- Issue:
- 16
- Issue Sort Value:
- 2016-0039-0016-0000
- Page Start:
- 3221
- Page End:
- 3229
- Publication Date:
- 2016-08-01
- Subjects:
- Dications -- Magnetic adsorbents -- Magnetic solid‐phase extraction -- Polymeric ionic liquids
Separation (Technology) -- Periodicals
Chromatographic analysis -- Periodicals
543.089 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1615-9314 ↗
http://www.interscience.wiley.com/jpages/1615-9306 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jssc.201600267 ↗
- Languages:
- English
- ISSNs:
- 1615-9306
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5063.880000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1350.xml