Evaluation of interobserver variability and diagnostic performance of developed MRI‐based radiological scoring system for invasive placenta previa. Issue 3 (21st February 2016)
- Record Type:
- Journal Article
- Title:
- Evaluation of interobserver variability and diagnostic performance of developed MRI‐based radiological scoring system for invasive placenta previa. Issue 3 (21st February 2016)
- Main Title:
- Evaluation of interobserver variability and diagnostic performance of developed MRI‐based radiological scoring system for invasive placenta previa
- Authors:
- Ueno, Yoshiko
Maeda, Tetsuo
Tanaka, Utaru
Tanimura, Kenji
Kitajima, Kazuhiro
Suenaga, Yuko
Takahashi, Satoru
Yamada, Hideto
Sugimura, Kazuro - Abstract:
- Abstract : Purpose: To evaluate the interobserver variability and diagnostic performance of a developed magnetic resonance imaging (MRI)‐based scoring system for invasive placenta previa. Materials and Methods: Prenatal MR images of 70 women were retrospectively evaluated, 18 of whom were diagnosed with invasive placenta. The six MR features (dark band on T 2 ‐weighted images, intraplacental abnormal vascularity, placental bulge, heterogeneous placenta, myometrial thinning, and placental protrusion sign) were scored on 5‐point Likert scale separately, and the cumulative radiological score (CRS) was defined as the sum of each score. Two more experienced radiologists (readers A and B) and two less experienced residents (readers C and D) calculated the CRS. Interobserver variability was assessed by measuring the intraclass correlation coefficient. Diagnostic performance was evaluated by means of receiver operating characteristic (ROC) analysis. Results: Interobserver variability for CRS was excellent for the more experienced radiologists (0.85), and good for all readers (0.72) and the less experienced residents (0.66). The area under the ROC curve (Az) and accuracy (Acc) for CRS were significantly higher or equivalent to those of other MR features for all readers (Az and Acc for reader A; CRS, 0.92, 91.4%; intraplacental T 2 dark band, 0.83, P = 0.009, 81.4%, P = 0.03; intraplacental abnormal vascularity, 0.9, P = 0.3, 90.0%, P = 1.00; placental bulge, 0.81, P = 0.0008,Abstract : Purpose: To evaluate the interobserver variability and diagnostic performance of a developed magnetic resonance imaging (MRI)‐based scoring system for invasive placenta previa. Materials and Methods: Prenatal MR images of 70 women were retrospectively evaluated, 18 of whom were diagnosed with invasive placenta. The six MR features (dark band on T 2 ‐weighted images, intraplacental abnormal vascularity, placental bulge, heterogeneous placenta, myometrial thinning, and placental protrusion sign) were scored on 5‐point Likert scale separately, and the cumulative radiological score (CRS) was defined as the sum of each score. Two more experienced radiologists (readers A and B) and two less experienced residents (readers C and D) calculated the CRS. Interobserver variability was assessed by measuring the intraclass correlation coefficient. Diagnostic performance was evaluated by means of receiver operating characteristic (ROC) analysis. Results: Interobserver variability for CRS was excellent for the more experienced radiologists (0.85), and good for all readers (0.72) and the less experienced residents (0.66). The area under the ROC curve (Az) and accuracy (Acc) for CRS were significantly higher or equivalent to those of other MR features for all readers (Az and Acc for reader A; CRS, 0.92, 91.4%; intraplacental T 2 dark band, 0.83, P = 0.009, 81.4%, P = 0.03; intraplacental abnormal vascularity, 0.9, P = 0.3, 90.0%, P = 1.00; placental bulge, 0.81, P = 0.0008, 80.0%, P = 0.02; heterogeneous placenta, 0.85, P = 0.11, 74.3%, P = 0.002; myometrial thinning, 0.84, P = 0.06, 60.0%, P < 0.0001; placental protrusion sign, 0.81, P = 0.01, 81.4%, P = 0.26). Conclusion: This developed MRI‐based scoring system demonstrated excellent or good interobserver variability, and good diagnostic performance for invasive placenta previa. J. Magn. Reson. Imaging 2016;44:573–583. … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 44:Issue 3(2016)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 44:Issue 3(2016)
- Issue Display:
- Volume 44, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 44
- Issue:
- 3
- Issue Sort Value:
- 2016-0044-0003-0000
- Page Start:
- 573
- Page End:
- 583
- Publication Date:
- 2016-02-21
- Subjects:
- placenta accreta -- invasive placenta -- prenatal diagnosis -- placenta previa -- MRI
Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.25184 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2123.xml