Design of a breast phantom for quantitative MRI. Issue 3 (7th March 2016)
- Record Type:
- Journal Article
- Title:
- Design of a breast phantom for quantitative MRI. Issue 3 (7th March 2016)
- Main Title:
- Design of a breast phantom for quantitative MRI
- Authors:
- Keenan, Kathryn E.
Wilmes, Lisa J.
Aliu, Sheye O.
Newitt, David C.
Jones, Ella F.
Boss, Michael A.
Stupic, Karl F.
Russek, Stephen E.
Hylton, Nola M. - Abstract:
- Abstract : Purpose: We present a breast phantom designed to enable quantitative assessment of measurements of T 1 relaxation time, apparent diffusion coefficient (ADC), and other attributes of breast tissue, with long‐term support from a national metrology institute. Materials and Methods: A breast phantom was created with two independent, interchangeable units for diffusion and T 1 / T 2 relaxation, each with flexible outer shells. The T 1 unit was filled with corn syrup solution and grapeseed oil to mimic the relaxation behavior of fibroglandular and fatty tissues, respectively. The diffusion unit contains plastic tubes filled with aqueous solutions of polyvinylpyrrolidone (PVP) to modulate the ADC. The phantom was imaged at 1.5T and 3.0T using magnetic resonance imaging (MRI) scanners and common breast coils from multiple manufacturers to assess T 1 and T 2 relaxation time and ADC values. Results: The fibroglandular mimic exhibited target T 1 values on 1.5T and 3.0T clinical systems (25–75 percentile range: 1289 to 1400 msec and 1533 to 1845 msec, respectively) across all bore temperatures. PVP solutions mimicked the range of ADC values from malignant tumors to normal breast tissue (40% PVP median: 633 × 10 −6 mm 2 /s to 0% PVP median: 2231 × 10 −6 mm 2 /s) at temperatures of 17–24°C. The interchangeable phantom units allowed both the diffusion and T 1 / T 2 units to be tested on the left and right sides of the coil to assess any variation. Conclusion: This phantomAbstract : Purpose: We present a breast phantom designed to enable quantitative assessment of measurements of T 1 relaxation time, apparent diffusion coefficient (ADC), and other attributes of breast tissue, with long‐term support from a national metrology institute. Materials and Methods: A breast phantom was created with two independent, interchangeable units for diffusion and T 1 / T 2 relaxation, each with flexible outer shells. The T 1 unit was filled with corn syrup solution and grapeseed oil to mimic the relaxation behavior of fibroglandular and fatty tissues, respectively. The diffusion unit contains plastic tubes filled with aqueous solutions of polyvinylpyrrolidone (PVP) to modulate the ADC. The phantom was imaged at 1.5T and 3.0T using magnetic resonance imaging (MRI) scanners and common breast coils from multiple manufacturers to assess T 1 and T 2 relaxation time and ADC values. Results: The fibroglandular mimic exhibited target T 1 values on 1.5T and 3.0T clinical systems (25–75 percentile range: 1289 to 1400 msec and 1533 to 1845 msec, respectively) across all bore temperatures. PVP solutions mimicked the range of ADC values from malignant tumors to normal breast tissue (40% PVP median: 633 × 10 −6 mm 2 /s to 0% PVP median: 2231 × 10 −6 mm 2 /s) at temperatures of 17–24°C. The interchangeable phantom units allowed both the diffusion and T 1 / T 2 units to be tested on the left and right sides of the coil to assess any variation. Conclusion: This phantom enables T 1 and ADC measurements, fits in a variety of clinical breast coils, and can serve as a quality control tool to facilitate the standardization of quantitative measurements for breast MRI. J. Magn. Reson. Imaging 2016;44:610–619. … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 44:Issue 3(2016)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 44:Issue 3(2016)
- Issue Display:
- Volume 44, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 44
- Issue:
- 3
- Issue Sort Value:
- 2016-0044-0003-0000
- Page Start:
- 610
- Page End:
- 619
- Publication Date:
- 2016-03-07
- Subjects:
- breast MRI -- apparent diffusion coefficient -- relaxation -- tissue mimic -- phantoms -- quality control
Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.25214 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2123.xml