Comparison of multislice breath‐hold and 3D respiratory triggered T1ρ imaging of liver in healthy volunteers and liver cirrhosis patients in 3.0 T MRI. Issue 4 (5th May 2016)
- Record Type:
- Journal Article
- Title:
- Comparison of multislice breath‐hold and 3D respiratory triggered T1ρ imaging of liver in healthy volunteers and liver cirrhosis patients in 3.0 T MRI. Issue 4 (5th May 2016)
- Main Title:
- Comparison of multislice breath‐hold and 3D respiratory triggered T1ρ imaging of liver in healthy volunteers and liver cirrhosis patients in 3.0 T MRI
- Authors:
- Yang, Qihua
Yu, Taihui
Yun, Su
Zhang, Hui
Chen, Xiaodong
Cheng, Ziliang
Zhong, Jinglian
Huang, Jingwen
Okuaki, Tomoyuki
Chan, Queenie
Liang, Biling
Guo, Hua - Abstract:
- Abstract : Purpose: To compare visual quality and quantitative measurements of multislice (MS) breath‐hold and 3D respiratory‐triggered T 1 ρ sequences. Materials and Methods: T 1 ρ scans including MS BLOCK T 1 ρ, MS HS8 T 1 ρ, and 3D BLOCK T 1 ρ were performed on 40 healthy volunteers and 17 liver cirrhosis patients on 3.0T magnetic resonance imaging (MRI). The MS breath‐hold methods scanned three slices while the 3D method covered 26 slices. Visual scores of image quality, T 1 ρ measurements of the three sequences, and T 1 ρ values of healthy volunteers and cirrhosis patients were compared using parametric tests. Results: Average visual scores for volunteers and patients of the three sequences were 3.19 and 2.82 for MS BLOCK T 1 ρ; 3.71 and 3.59 for MS HS8 T 1 ρ; 3.29 and 3.59 for 3D BLOCK T 1 ρ, respectively. Difference of visual scores among the three groups was significant ( P < 0.001). Differences in T 1 ρ values among the three methods were significant ( P < 0.001). Difference of T 1 ρ between MS BLOCK T 1 ρ and 3D BLOCK T 1 ρ was not significant (volunteer: P = 0.82, patient: 0.92) while the difference of T 1 ρ between MS BLOCK T 1 ρ and MS HS8 T 1 ρ, MS HS8 T 1 ρ and 3D BLOCK T 1 ρ was significant in both volunteers and patients ( P < 0.01). Differences of T 1 ρ between healthy volunteers and patients were all significant in three T 1 ρ sequences ( P = 0.04, 0.004, 0.03). Conclusion: Of the tested sequences, the image quality of MS HS8 T 1 ρ was best, but 3D BLOCK TAbstract : Purpose: To compare visual quality and quantitative measurements of multislice (MS) breath‐hold and 3D respiratory‐triggered T 1 ρ sequences. Materials and Methods: T 1 ρ scans including MS BLOCK T 1 ρ, MS HS8 T 1 ρ, and 3D BLOCK T 1 ρ were performed on 40 healthy volunteers and 17 liver cirrhosis patients on 3.0T magnetic resonance imaging (MRI). The MS breath‐hold methods scanned three slices while the 3D method covered 26 slices. Visual scores of image quality, T 1 ρ measurements of the three sequences, and T 1 ρ values of healthy volunteers and cirrhosis patients were compared using parametric tests. Results: Average visual scores for volunteers and patients of the three sequences were 3.19 and 2.82 for MS BLOCK T 1 ρ; 3.71 and 3.59 for MS HS8 T 1 ρ; 3.29 and 3.59 for 3D BLOCK T 1 ρ, respectively. Difference of visual scores among the three groups was significant ( P < 0.001). Differences in T 1 ρ values among the three methods were significant ( P < 0.001). Difference of T 1 ρ between MS BLOCK T 1 ρ and 3D BLOCK T 1 ρ was not significant (volunteer: P = 0.82, patient: 0.92) while the difference of T 1 ρ between MS BLOCK T 1 ρ and MS HS8 T 1 ρ, MS HS8 T 1 ρ and 3D BLOCK T 1 ρ was significant in both volunteers and patients ( P < 0.01). Differences of T 1 ρ between healthy volunteers and patients were all significant in three T 1 ρ sequences ( P = 0.04, 0.004, 0.03). Conclusion: Of the tested sequences, the image quality of MS HS8 T 1 ρ was best, but 3D BLOCK T 1 ρ with respiratory triggering should also be considered as an alternative sequence for clinical diagnosis of liver cirrhosis due to its superior coverage. J. MAGN. RESON. IMAGING 2016;44:906–913. … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 44:Issue 4(2016)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 44:Issue 4(2016)
- Issue Display:
- Volume 44, Issue 4 (2016)
- Year:
- 2016
- Volume:
- 44
- Issue:
- 4
- Issue Sort Value:
- 2016-0044-0004-0000
- Page Start:
- 906
- Page End:
- 913
- Publication Date:
- 2016-05-05
- Subjects:
- liver imaging -- T1ρ imaging -- liver cirrhosis -- T1ρ mapping
Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.25253 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 371.xml