Free‐breathing variable flip angle balanced SSFP cardiac cine imaging with reduced SAR at 3T. Issue 4 (28th October 2015)
- Record Type:
- Journal Article
- Title:
- Free‐breathing variable flip angle balanced SSFP cardiac cine imaging with reduced SAR at 3T. Issue 4 (28th October 2015)
- Main Title:
- Free‐breathing variable flip angle balanced SSFP cardiac cine imaging with reduced SAR at 3T
- Authors:
- Srinivasan, Subashini
Kroeker, Randall M.
Gabriel, Simon
Plotnik, Adam
Godinez, Sergio R.
Hu, Peng
Halnon, Nancy
Finn, J. Paul
Ennis, Daniel B. - Abstract:
- Abstract : Purpose: To develop a free‐breathing variable flip angle (VFA) balanced steady‐state free precession (bSSFP) cardiac cine imaging technique with reduced specific absorption rate (SAR) at 3 Tesla. Methods: Free‐breathing VFA (FB‐VFA) images in the short‐axis and four‐chamber views were acquired using an optimal VFA scheme, then compared with conventional breath‐hold constant flip angle (BH‐CFA) acquisitions. Two cardiac MRI experts used a 5‐point scale to score images from healthy subjects (N = 10). The left ventricular ejection fraction, end diastolic volume (LVEDV), end systolic volume, stroke volume (LVSV), and end diastolic myocardial mass (LVEDM) were determined by manual contour analysis for BH‐CFA and FB‐VFA. A pilot evaluation of FB‐VFA was performed in one patient with Duchenne muscular dystrophy. Results: FB‐VFA SAR was 25% lower than BH‐CFA with similar blood–myocardium contrast. The qualitative FB‐VFA score was lower than the BH‐CFA for the short‐axis (3.1 ± 0.5 versus 4.3 ± 0.8; P < 0.05) and the four‐chamber view (3.4 ± 0.4 versus 4.6 ± 0.6; P < 0.05). The LVEDV and the LVSV were 5% and 12% larger ( P < 0.05) for FB‐VFA compared with BH‐CFA. There was no difference in LVEDM. Conclusion: FB‐VFA bSSFP cardiac cine imaging decreased the SAR at 3T with image quality sufficient to perform cardiac functional analysis. Magn Reson Med 76:1210–1216, 2016. © 2015 Wiley Periodicals, Inc.
- Is Part Of:
- Magnetic resonance in medicine. Volume 76:Issue 4(2016)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 76:Issue 4(2016)
- Issue Display:
- Volume 76, Issue 4 (2016)
- Year:
- 2016
- Volume:
- 76
- Issue:
- 4
- Issue Sort Value:
- 2016-0076-0004-0000
- Page Start:
- 1210
- Page End:
- 1216
- Publication Date:
- 2015-10-28
- Subjects:
- free‐breathing cardiac cine imaging -- variable flip angle -- bSSFP
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.26011 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 304.xml