The dosimetric impact of target volume delineation variation for cervical cancer radiotherapy. Issue 3 (September 2016)
- Record Type:
- Journal Article
- Title:
- The dosimetric impact of target volume delineation variation for cervical cancer radiotherapy. Issue 3 (September 2016)
- Main Title:
- The dosimetric impact of target volume delineation variation for cervical cancer radiotherapy
- Authors:
- Eminowicz, Gemma
Rompokos, Vasilis
Stacey, Christopher
McCormack, Mary - Abstract:
- Abstract: Background: Cervical cancer inter-observer delineation variation has been demonstrated. This article addresses its dosimetric impact. Methods: 21 centres outlined two INTERLACE trial quality assurance test cases. A gold standard clinical target volume (GSCTV) was created from a consensus and STAPLE outline. RapidArc plans were created for all centres' planning target volumes (PTVs; PTV1 + 2). Gold standard PTVs (GSPTVs) were created for each plan by applying each centre's CTV–PTV margins to GSCTV. DVH parameters including D95% and Dmean for each PTV1 + 2 and GSPTV were compared, representing planned versus GSPTV delivered dose. PTV1 + 2 and GSPTV V95% was also calculated. Results: Reviewing all parameters, no plans achieved acceptable GSPTV coverage. GSPTV V95% ⩾ 95% was not achieved for any plan. GSPTV V95% < 90% in 15/21 (case 1) and 14/22 (case 2) and <80% in 2 plans from both cases. GSPTV V95% is on average 10–15% lower than planned and GSPTV D95% is 10–20% lower than planned. Most common GSCTV anatomical areas not receiving 95% dose were vagina, obturator and external iliac nodes and, in case 1, the superior nodal aspect. Conclusion: Cervical cancer CTV delineation variation leads to significant reductions in dose delivered to GSPTV. This highlights the ongoing importance of standardising delineation in the IMRT era.
- Is Part Of:
- Radiotherapy and oncology. Volume 120:Issue 3(2016:Sep.)
- Journal:
- Radiotherapy and oncology
- Issue:
- Volume 120:Issue 3(2016:Sep.)
- Issue Display:
- Volume 120, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 120
- Issue:
- 3
- Issue Sort Value:
- 2016-0120-0003-0000
- Page Start:
- 493
- Page End:
- 499
- Publication Date:
- 2016-09
- Subjects:
- Cervical cancer radiotherapy -- Inter-observer variation -- Dosimetry
Oncology -- Periodicals
Radiotherapy -- Periodicals
Tumors -- Periodicals
Medical Oncology -- Periodicals
Neoplasms -- radiotherapy -- Periodicals
Radiotherapy -- Periodicals
Radiothérapie -- Périodiques
Cancérologie -- Périodiques
Tumeurs -- Périodiques
Electronic journals
616.9940642 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01678140 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/01678140 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/01678140 ↗
http://www.estro.org/ ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiotherapy-and-oncology/ ↗ - DOI:
- 10.1016/j.radonc.2016.04.028 ↗
- Languages:
- English
- ISSNs:
- 0167-8140
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7240.790000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1755.xml