A new image quality measure in CT: Feasibility of a contrast-detail measurement method. Issue 4 (November 2016)
- Record Type:
- Journal Article
- Title:
- A new image quality measure in CT: Feasibility of a contrast-detail measurement method. Issue 4 (November 2016)
- Main Title:
- A new image quality measure in CT: Feasibility of a contrast-detail measurement method
- Authors:
- Davidson, R.
Alsleem, H.
Floor, M.
van der Burght, R. - Abstract:
- Abstract: Purpose: To develop a new method of evaluating image quality in computed tomography (CT) using an objective measure of low contrast-detail (LCD). Method: To achieve this aim a new LCD-CT (CDCT) phantom needed to be designed and developed. A CT inverse image quality figure (CT-IQFinv) value, based on the planar radiography LCD method, was also devised. Validation of the CDCT phantom design and CT-IQFinv calculations were undertaken using 67 observers and software methods. The CDCT phantom was scanned on three multi-detector CT systems using variable factors of kVp, mAs and slice thickness. Results: The results were compared to an a priori knowledge that image quality improves with increased photons reaching the detectors. Observer CT-IQFinv scores for the phantom's peripheral region were consistent with the a priori knowledge and generally consistent in the inner region, with one exception. The software CT-IQFinv scores for the phantom's peripheral region were also consistent with the a priori knowledge, however there were some inconsistencies. Software and observer CT-IQFinv score differed significantly ( p < 0.05) however both were consistent with the a priori knowledge. Conclusions: The work reported is designed as proof of concept of development of LCD measure in CT. CT-IQFinv can be used as a measure of LCD image quality in CT when evaluating CT parameter of mAs, kVp and slice thickness. The results demonstrate potential for use of CT IQFinv, however atAbstract: Purpose: To develop a new method of evaluating image quality in computed tomography (CT) using an objective measure of low contrast-detail (LCD). Method: To achieve this aim a new LCD-CT (CDCT) phantom needed to be designed and developed. A CT inverse image quality figure (CT-IQFinv) value, based on the planar radiography LCD method, was also devised. Validation of the CDCT phantom design and CT-IQFinv calculations were undertaken using 67 observers and software methods. The CDCT phantom was scanned on three multi-detector CT systems using variable factors of kVp, mAs and slice thickness. Results: The results were compared to an a priori knowledge that image quality improves with increased photons reaching the detectors. Observer CT-IQFinv scores for the phantom's peripheral region were consistent with the a priori knowledge and generally consistent in the inner region, with one exception. The software CT-IQFinv scores for the phantom's peripheral region were also consistent with the a priori knowledge, however there were some inconsistencies. Software and observer CT-IQFinv score differed significantly ( p < 0.05) however both were consistent with the a priori knowledge. Conclusions: The work reported is designed as proof of concept of development of LCD measure in CT. CT-IQFinv can be used as a measure of LCD image quality in CT when evaluating CT parameter of mAs, kVp and slice thickness. The results demonstrate potential for use of CT IQFinv, however at present further work is needed to overcome design and technical issue encountered in this project. Highlights: A new CT contrast detail phantom has been designed and validated. Low contrast detail can be measured in CT using a new value, the CT inverse image quality figure (CT IQFinv). CT image quality can be measured and protocols assessed using the CT IQFinv as the measure. … (more)
- Is Part Of:
- Radiography. Volume 22:Issue 4(2016)
- Journal:
- Radiography
- Issue:
- Volume 22:Issue 4(2016)
- Issue Display:
- Volume 22, Issue 4 (2016)
- Year:
- 2016
- Volume:
- 22
- Issue:
- 4
- Issue Sort Value:
- 2016-0022-0004-0000
- Page Start:
- 274
- Page End:
- 281
- Publication Date:
- 2016-11
- Subjects:
- Computed tomography -- Image quality -- Low contrast detail -- CT-IQFinv
Diagnostic imaging -- Periodicals
Radiotherapy -- Periodicals
Cancer -- Radiotherapy -- Periodicals
Diagnostic Imaging -- Periodicals
Neoplasms -- Periodicals
Radiotherapy -- Periodicals
Imagerie pour le diagnostic -- Périodiques
Radiothérapie -- Périodiques
Cancer -- Radiothérapie -- Périodiques
Electronic journals
616.0757 - Journal URLs:
- http://www.sciencedirect.com/science/journal/10788174 ↗
http://www.radiographyonline.com/ ↗
http://www.harcourt-international.com/journals ↗
http://www.idealibrary.com/links/toc/radi/ ↗
http://www.clinicalkey.com/dura/browse/journalIssue/10788174 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/10788174 ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiography/ ↗ - DOI:
- 10.1016/j.radi.2016.04.003 ↗
- Languages:
- English
- ISSNs:
- 1078-8174
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7237.001000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 2769.xml