Determinants of temporal changes in galectin-3 level in the general population: Data of PREVEND. (1st November 2016)
- Record Type:
- Journal Article
- Title:
- Determinants of temporal changes in galectin-3 level in the general population: Data of PREVEND. (1st November 2016)
- Main Title:
- Determinants of temporal changes in galectin-3 level in the general population: Data of PREVEND
- Authors:
- van der Velde, A. Rogier
Meijers, Wouter C.
van den Heuvel, Edwin R.
Bakker, Stephan J.
van Gilst, Wiek H.
van der Harst, Pim
Hillege, Hans
de Boer, Rudolf A. - Abstract:
- Abstract: Background: High baseline galectin-3 levels are associated with increased risk for adverse cardiovascular outcomes in the general population, but determinants of changes in galectin-3 levels over time have not been established. Therefore, we aimed to identify determinants of (temporal) change in galectin-3 levels. Methods: Galectin-3 plasma levels were measured in a large community based cohort (PREVEND study) at 3 different time points: at baseline, after ~ 4 and ~ 9 years. The association of baseline clinical and biochemical factors and (temporal) changes in galectin-3 level was assessed using multivariable mixed-effects regression modeling. Results: In 4355 subjects, galectin-3 plasma levels were available at all time points (mean age: 48 ± 12 years; 50% female). Median galectin-3 level at baseline was 10.7 [8.9–12.7] ng/mL which gradually increased to 11.5 [9.4–14.3] ng/mL after ~ 9 years. Using mixed-effects regression modeling, we first validated as independent determinants of baseline circulating galectin-3: eGFR (chi square (χ 2 ):210.27, p < 0.0001), gender (χ 2 :43.85; p < 0.0001), BMI (χ 2 :19.68, p = 0.0001), NT-proBNP (χ 2 :18.76, p = 0.0001) and serum (total) cholesterol (χ 2 :8.63, p = 0.01). Furthermore, we identified urinary albumin excretion (χ 2 :34.03, p-value: < 0.0001) and systolic blood pressure (χ 2 :16.81, p = 0.002) as independent determinants of temporal changes of galectin-3. Conclusions: In the general population, urinary albuminAbstract: Background: High baseline galectin-3 levels are associated with increased risk for adverse cardiovascular outcomes in the general population, but determinants of changes in galectin-3 levels over time have not been established. Therefore, we aimed to identify determinants of (temporal) change in galectin-3 levels. Methods: Galectin-3 plasma levels were measured in a large community based cohort (PREVEND study) at 3 different time points: at baseline, after ~ 4 and ~ 9 years. The association of baseline clinical and biochemical factors and (temporal) changes in galectin-3 level was assessed using multivariable mixed-effects regression modeling. Results: In 4355 subjects, galectin-3 plasma levels were available at all time points (mean age: 48 ± 12 years; 50% female). Median galectin-3 level at baseline was 10.7 [8.9–12.7] ng/mL which gradually increased to 11.5 [9.4–14.3] ng/mL after ~ 9 years. Using mixed-effects regression modeling, we first validated as independent determinants of baseline circulating galectin-3: eGFR (chi square (χ 2 ):210.27, p < 0.0001), gender (χ 2 :43.85; p < 0.0001), BMI (χ 2 :19.68, p = 0.0001), NT-proBNP (χ 2 :18.76, p = 0.0001) and serum (total) cholesterol (χ 2 :8.63, p = 0.01). Furthermore, we identified urinary albumin excretion (χ 2 :34.03, p-value: < 0.0001) and systolic blood pressure (χ 2 :16.81, p = 0.002) as independent determinants of temporal changes of galectin-3. Conclusions: In the general population, urinary albumin excretion > 30 mg/24 h and systolic blood pressure > 170 mmHg were identified as significant determinants of dynamic increases in galectin-3 levels over time. These results implicate that treatment of high blood pressure might be effective to prevent increasing galectin-3 levels and its associated conditions. … (more)
- Is Part Of:
- International journal of cardiology. Volume 222(2016)
- Journal:
- International journal of cardiology
- Issue:
- Volume 222(2016)
- Issue Display:
- Volume 222, Issue 2016 (2016)
- Year:
- 2016
- Volume:
- 222
- Issue:
- 2016
- Issue Sort Value:
- 2016-0222-2016-0000
- Page Start:
- 385
- Page End:
- 390
- Publication Date:
- 2016-11-01
- Subjects:
- Biomarker -- Galectin-3 -- Blood pressure -- Serial measurements
Cardiology -- Periodicals
Electronic journals
616.12 - Journal URLs:
- http://www.clinicalkey.com/dura/browse/journalIssue/01675273 ↗
http://www.sciencedirect.com/science/journal/01675273 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijcard.2016.07.241 ↗
- Languages:
- English
- ISSNs:
- 0167-5273
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.158000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1869.xml