Influence of remote monitoring on long-term cardiovascular outcomes after cardioverter-defibrillator implantation. (1st November 2016)
- Record Type:
- Journal Article
- Title:
- Influence of remote monitoring on long-term cardiovascular outcomes after cardioverter-defibrillator implantation. (1st November 2016)
- Main Title:
- Influence of remote monitoring on long-term cardiovascular outcomes after cardioverter-defibrillator implantation
- Authors:
- Portugal, Guilherme
Cunha, Pedro
Valente, Bruno
Feliciano, Joana
Lousinha, Ana
Alves, Sandra
Braz, Manuel
Pimenta, Ricardo
Delgado, Ana Sofia
Oliveira, Mário
Ferreira, Rui C. - Abstract:
- Abstract: Aims: Device-based remote monitoring (RM) has been linked to improved clinical outcomes at short to medium-term follow-up. Whether this benefit extends to long-term follow-up is unknown. We sought to assess the effect of device-based RM on long-term clinical outcomes in recipients of implantable cardioverter-defibrillators (ICD). Methods: We performed a retrospective cohort study of consecutive patients who underwent ICD implantation for primary prevention. RM was initiated with patient consent according to availability of RM hardware at implantation. Patients with concomitant cardiac resynchronization therapy were excluded. Data on hospitalizations, mortality and cause of death were systematically assessed using a nationwide healthcare platform. A Cox proportional hazards model was employed to estimate the effect of RM on mortality and a composite endpoint of cardiovascular mortality and hospital admission due to heart failure (HF). Results: 312 patients were included with a median follow-up of 37.7 months (range 1 to 146). 121 patients (38.2%) were under RM since the first outpatient visit post-ICD and 191 were in conventional follow-up. No differences were found regarding age, left ventricular ejection fraction, heart failure etiology or NYHA class at implantation. Patients under RM had higher long-term survival (hazard ratio [HR] 0.50, CI 0.27–0.93, p = 0.029) and lower incidence of the composite outcome (HR 0.47, CI 0.27–0.82, p = 0.008). After multivariateAbstract: Aims: Device-based remote monitoring (RM) has been linked to improved clinical outcomes at short to medium-term follow-up. Whether this benefit extends to long-term follow-up is unknown. We sought to assess the effect of device-based RM on long-term clinical outcomes in recipients of implantable cardioverter-defibrillators (ICD). Methods: We performed a retrospective cohort study of consecutive patients who underwent ICD implantation for primary prevention. RM was initiated with patient consent according to availability of RM hardware at implantation. Patients with concomitant cardiac resynchronization therapy were excluded. Data on hospitalizations, mortality and cause of death were systematically assessed using a nationwide healthcare platform. A Cox proportional hazards model was employed to estimate the effect of RM on mortality and a composite endpoint of cardiovascular mortality and hospital admission due to heart failure (HF). Results: 312 patients were included with a median follow-up of 37.7 months (range 1 to 146). 121 patients (38.2%) were under RM since the first outpatient visit post-ICD and 191 were in conventional follow-up. No differences were found regarding age, left ventricular ejection fraction, heart failure etiology or NYHA class at implantation. Patients under RM had higher long-term survival (hazard ratio [HR] 0.50, CI 0.27–0.93, p = 0.029) and lower incidence of the composite outcome (HR 0.47, CI 0.27–0.82, p = 0.008). After multivariate survival analysis, overall survival was independently associated with younger age, higher LVEF, NYHA class lower than 3 and RM. Conclusion: RM was independently associated with increased long-term survival and a lower incidence of a composite endpoint of hospitalization for HF or cardiovascular mortality. … (more)
- Is Part Of:
- International journal of cardiology. Volume 222(2016)
- Journal:
- International journal of cardiology
- Issue:
- Volume 222(2016)
- Issue Display:
- Volume 222, Issue 2016 (2016)
- Year:
- 2016
- Volume:
- 222
- Issue:
- 2016
- Issue Sort Value:
- 2016-0222-2016-0000
- Page Start:
- 764
- Page End:
- 768
- Publication Date:
- 2016-11-01
- Subjects:
- Remote monitoring -- ICD
Cardiology -- Periodicals
Electronic journals
616.12 - Journal URLs:
- http://www.clinicalkey.com/dura/browse/journalIssue/01675273 ↗
http://www.sciencedirect.com/science/journal/01675273 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijcard.2016.07.157 ↗
- Languages:
- English
- ISSNs:
- 0167-5273
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.158000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1870.xml