Comparative Performance between Two Photogrammetric Systems and a Reference Laser Tracker Network for Large‐Volume Industrial Measurement. (4th September 2016)
- Record Type:
- Journal Article
- Title:
- Comparative Performance between Two Photogrammetric Systems and a Reference Laser Tracker Network for Large‐Volume Industrial Measurement. (4th September 2016)
- Main Title:
- Comparative Performance between Two Photogrammetric Systems and a Reference Laser Tracker Network for Large‐Volume Industrial Measurement
- Authors:
- Martin, Oliver C.
Robson, Stuart
Kayani, Amir
Muelaner, Jody E.
Dhokia, Vimal
Maropoulos, Paul. G. - Abstract:
- Abstract: This paper determines the capability of two photogrammetric systems in terms of their measurement uncertainty in an industrial context. The first system – V‐STARSinca 3 from Geodetic Systems Inc. – is a commercially available measurement solution. The second system comprises an off‐the‐shelf Nikon D700 digital camera fitted with a 28 mm Nikkor lens and the research‐based Vision Measurement Software (VMS). The uncertainty estimate of these two systems is determined with reference to a calibrated constellation of points determined by a Leica AT401 laser tracker. The calibrated points have an average associated standard uncertainty of 12·4 μm, spanning a maximum distance of approximately 14·5 m. Subsequently, the two systems' uncertainty was determined. V‐STARSinca 3 had an estimated standard uncertainty of 43·1 μm, thus outperforming its manufacturer's specification; the D700/VMS combination achieved a standard uncertainty of 187 μm.
- Is Part Of:
- Photogrammetric record. Volume 31:Number 155(2016:Sep.)
- Journal:
- Photogrammetric record
- Issue:
- Volume 31:Number 155(2016:Sep.)
- Issue Display:
- Volume 31, Issue 155 (2016)
- Year:
- 2016
- Volume:
- 31
- Issue:
- 155
- Issue Sort Value:
- 2016-0031-0155-0000
- Page Start:
- 348
- Page End:
- 360
- Publication Date:
- 2016-09-04
- Subjects:
- coordinate comparison -- laser tracker -- photogrammetry -- uncertainty -- V‐STARS
Photogrammetry -- Periodicals
526.982 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1477-9730 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/phor.12154 ↗
- Languages:
- English
- ISSNs:
- 0031-868X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6468.100000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 621.xml