Use of a prospective cohort study in the development of a bladder scanning protocol to assist in bladder filling consistency for prostate cancer patients receiving radiation therapy. Issue 3 (23rd February 2016)
- Record Type:
- Journal Article
- Title:
- Use of a prospective cohort study in the development of a bladder scanning protocol to assist in bladder filling consistency for prostate cancer patients receiving radiation therapy. Issue 3 (23rd February 2016)
- Main Title:
- Use of a prospective cohort study in the development of a bladder scanning protocol to assist in bladder filling consistency for prostate cancer patients receiving radiation therapy
- Authors:
- Cramp, Leah
Connors, Vanessa
Wood, Maree
Westhuyzen, Justin
McKay, Michael
Greenham, Stuart - Abstract:
- Abstract : This study aimed to increase bladder filling reproducibility for prostate radiation therapy patients by implementing a method of assessing patients' bladder volume at computed tomography (CT) simulation, using an ultrasound bladder scanner (Verathon 9400 BladderScan). Results found that the routine use of the Bladder Scanner has increased scheduled treatment efficiency and potentially improved patient care. Abstract: Introduction: Evidence of variations in bladder filling effecting prostate stability and therefore treatment and side‐effects is well established with intensity modulated radiation therapy (IMRT). This study aimed to increase bladder volume reproducibility for prostate radiation therapy by implementing a bladder scanning (BS) protocol that could assist patients' bladder filling at computed tomography (CT) simulation and treatment. Methods: Based on a retrospective review of 524 prostate cancer patients, a bladder volume of 250–350 mL was adopted as 'ideal' for achieving planning dose constraints. A prospective cohort study was conducted to assess the clinical utility of measuring patients' bladder volumes at CT simulation using an ultrasound bladder scanner (Verathon 9400 BladderScan ® ). A revised bladder preparation protocol was utilised by a bladder scan group (BS) and a non‐BS group followed the standard departmental bladder preparation protocol. Time and volume data for the BS group ( n = 17) were compared with the non‐BS group ( n = 17).Abstract : This study aimed to increase bladder filling reproducibility for prostate radiation therapy patients by implementing a method of assessing patients' bladder volume at computed tomography (CT) simulation, using an ultrasound bladder scanner (Verathon 9400 BladderScan). Results found that the routine use of the Bladder Scanner has increased scheduled treatment efficiency and potentially improved patient care. Abstract: Introduction: Evidence of variations in bladder filling effecting prostate stability and therefore treatment and side‐effects is well established with intensity modulated radiation therapy (IMRT). This study aimed to increase bladder volume reproducibility for prostate radiation therapy by implementing a bladder scanning (BS) protocol that could assist patients' bladder filling at computed tomography (CT) simulation and treatment. Methods: Based on a retrospective review of 524 prostate cancer patients, a bladder volume of 250–350 mL was adopted as 'ideal' for achieving planning dose constraints. A prospective cohort study was conducted to assess the clinical utility of measuring patients' bladder volumes at CT simulation using an ultrasound bladder scanner (Verathon 9400 BladderScan ® ). A revised bladder preparation protocol was utilised by a bladder scan group (BS) and a non‐BS group followed the standard departmental bladder preparation protocol. Time and volume data for the BS group ( n = 17) were compared with the non‐BS group ( n = 17). Results: The BS cohort had a CT bladder volume range of 221–588 mL; mean 379 mL, SD 125 mL. The non‐BS group had a larger range: 184–757 mL; mean 373 mL, SD 160 mL ( P = 0.9171). There was a positive correlation between CT volume and BS volume in the BS group ( r = 0.797; P = 0.0002) although BS volumes were smaller: range 160–420 mL; mean 251 mL; SD 91 mL; P < 0.0001). The maximum bladder volume receiving 50 Gy (V50) from the BS group was 46.4%, mean 24.5%. The maximum bladder V50 from the non‐BS group was 50.9%, mean 27.3% ( P = 0.5178). Treatment data from weekly cone beam CT scans were also compared over 6 weeks. They were assessed as being a pass if bladder and bowel requirements were acceptable. The BS group proceeded to treatment on the basis of a pass 92.7% of the time, whereas the pass rate for non‐BS group was 75%; difference 17.7% ( P < 0.0001). Conclusion: The BS is a useful tool for achieving consistent, appropriately sized bladder volumes in prostate cancer patients. … (more)
- Is Part Of:
- Journal of medical radiation sciences. Volume 63:Issue 3(2016:Sep.)
- Journal:
- Journal of medical radiation sciences
- Issue:
- Volume 63:Issue 3(2016:Sep.)
- Issue Display:
- Volume 63, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 63
- Issue:
- 3
- Issue Sort Value:
- 2016-0063-0003-0000
- Page Start:
- 179
- Page End:
- 185
- Publication Date:
- 2016-02-23
- Subjects:
- Diagnostic imaging -- prostate -- radiotherapy -- ultrasonography -- urinary bladder
Radiology, Medical -- Periodicals
Radiology, Medical -- Australia -- Periodicals
Radiology, Medical -- New Zealand -- Periodicals
Radiotherapy -- Periodicals
Diagnostic imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)2051-3909 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmrs.162 ↗
- Languages:
- English
- ISSNs:
- 2051-3895
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 473.xml