Concept of an upright wearable positron emission tomography imager in humans. Issue 9 (5th August 2016)
- Record Type:
- Journal Article
- Title:
- Concept of an upright wearable positron emission tomography imager in humans. Issue 9 (5th August 2016)
- Main Title:
- Concept of an upright wearable positron emission tomography imager in humans
- Authors:
- Bauer, Christopher E.
Brefczynski‐Lewis, Julie
Marano, Gary
Mandich, Mary‐Beth
Stolin, Alexander
Martone, Peter
Lewis, James W.
Jaliparthi, Gangadhar
Raylman, Raymond R.
Majewski, Stan - Abstract:
- Abstract: Background: Positron Emission Tomography (PET) is traditionally used to image patients in restrictive positions, with few devices allowing for upright, brain‐dedicated imaging. Our team has explored the concept of wearable PET imagers which could provide functional brain imaging of freely moving subjects. To test feasibility and determine future considerations for development, we built a rudimentary proof‐of‐concept prototype (Helmet_PET) and conducted tests in phantoms and four human volunteers. Methods: Twelve Silicon Photomultiplier‐based detectors were assembled in a ring with exterior weight support and an interior mechanism that could be adjustably fitted to the head. We conducted brain phantom tests as well as scanned four patients scheduled for diagnostic F 18‐ FDG PET/CT imaging. For human subjects the imager was angled such that field of view included basal ganglia and visual cortex to test for typical resting‐state pattern. Imaging in two subjects was performed ~4 hr after PET/CT imaging to simulate lower injected F 18‐ FDG dose by taking advantage of the natural radioactive decay of the tracer (F 18 half‐life of 110 min), with an estimated imaging dosage of 25% of the standard. Results: We found that imaging with a simple lightweight ring of detectors was feasible using a fraction of the standard radioligand dose. Activity levels in the human participants were quantitatively similar to standard PET in a set of anatomical ROIs. Typical resting‐stateAbstract: Background: Positron Emission Tomography (PET) is traditionally used to image patients in restrictive positions, with few devices allowing for upright, brain‐dedicated imaging. Our team has explored the concept of wearable PET imagers which could provide functional brain imaging of freely moving subjects. To test feasibility and determine future considerations for development, we built a rudimentary proof‐of‐concept prototype (Helmet_PET) and conducted tests in phantoms and four human volunteers. Methods: Twelve Silicon Photomultiplier‐based detectors were assembled in a ring with exterior weight support and an interior mechanism that could be adjustably fitted to the head. We conducted brain phantom tests as well as scanned four patients scheduled for diagnostic F 18‐ FDG PET/CT imaging. For human subjects the imager was angled such that field of view included basal ganglia and visual cortex to test for typical resting‐state pattern. Imaging in two subjects was performed ~4 hr after PET/CT imaging to simulate lower injected F 18‐ FDG dose by taking advantage of the natural radioactive decay of the tracer (F 18 half‐life of 110 min), with an estimated imaging dosage of 25% of the standard. Results: We found that imaging with a simple lightweight ring of detectors was feasible using a fraction of the standard radioligand dose. Activity levels in the human participants were quantitatively similar to standard PET in a set of anatomical ROIs. Typical resting‐state brain pattern activation was demonstrated even in a 1 min scan of active head rotation. Conclusion: To our knowledge, this is the first demonstration of imaging a human subject with a novel wearable PET imager that moves with robust head movements. We discuss potential research and clinical applications that will drive the design of a fully functional device. Designs will need to consider trade‐offs between a low weight device with high mobility and a heavier device with greater sensitivity and larger field of view. Abstract : We explore the possibility of mobile brain imaging using a wearable PET imaging prototype device that fits tightly around the head. This prototype collected data from both brain phantoms and human participants during intentional head rotation. We discuss the implications of the resulting images in both research and clinical terms, as well as future design considerations to further enhance wearable PET brain imaging technology. … (more)
- Is Part Of:
- Brain and behavior. Volume 6:Issue 9(2016)
- Journal:
- Brain and behavior
- Issue:
- Volume 6:Issue 9(2016)
- Issue Display:
- Volume 6, Issue 9 (2016)
- Year:
- 2016
- Volume:
- 6
- Issue:
- 9
- Issue Sort Value:
- 2016-0006-0009-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2016-08-05
- Subjects:
- brain imaging -- functional imaging -- mobile imaging -- molecular imaging -- positron emission tomography -- upright imaging
Neurology -- Periodicals
Neurosciences -- Periodicals
Psychology -- Periodicals
Psychiatry -- Periodicals
616.8005 - Journal URLs:
- http://bibpurl.oclc.org/web/52745 \u http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)2157-9032 ↗
http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)2157-9032 ↗
http://www.ncbi.nlm.nih.gov/pmc/journals/1650 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/brb3.530 ↗
- Languages:
- English
- ISSNs:
- 2162-3279
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 2776.xml