Discrepancy between frequency domain optical coherence tomography and intravascular ultrasound in human coronary arteries and in a phantom in vitro coronary model. (15th October 2016)
- Record Type:
- Journal Article
- Title:
- Discrepancy between frequency domain optical coherence tomography and intravascular ultrasound in human coronary arteries and in a phantom in vitro coronary model. (15th October 2016)
- Main Title:
- Discrepancy between frequency domain optical coherence tomography and intravascular ultrasound in human coronary arteries and in a phantom in vitro coronary model
- Authors:
- Kim, In-Cheol
Nam, Chang-Wook
Cho, Yun-Kyeong
Park, Hyoung-Seob
Yoon, Hyuck-Jun
Kim, Hyungseop
Chung, In-Sung
Han, Seongwook
Hur, Seung-Ho
Kim, Yoon-Nyun
Kim, Kwon-Bae - Abstract:
- Abstract: Background: This purpose of this study is to evaluate, concomitantly with quantitative coronary angiography (QCA), the potential discrepancy between frequency domain optical coherence tomography (FD-OCT) and intravascular ultrasound (IVUS) measurements in a phantom coronary model and in human coronary arteries within and outside stented segments. Methods: FD-OCT and IVUS images sequentially obtained from a phantom coronary model and 57 stented human coronary arteries were compared between each other and with QCA. Results: Lumen area (LA) by IVUS was 10.1% larger (6.43 ± 0.09 mm 2 ) while by FD-OCT was similar (5.78 ± 0.09 mm 2 ) to actual phantom LA (5.72 mm 2 ); IVUS vs. FD-OCT stent area (SA) was 4.2% larger. In human coronary artery, diameter by QCA was smaller than by IVUS and OCT in reference (by 10.5% and 3.5%, both p < 0.001) and stented (3.6%, p < 0.001; and 1.7%, p = 0.012) segments. IVUS vs. FD-OCT distal reference LA was significantly larger (6.19 ± 2.18 mm 2 vs. 5.49 ± 2.49 mm 2, p < 0.001, respectively), and SA was numerically larger (7.42 ± 2.28 mm 2 vs. 7.22 ± 2.48 mm 2, p = 0.059) with larger discrepancy in reference (11.3%) than stented (2.7%) segments. IVUS vs. FD-OCT correlation for diameter was significantly higher for stented than reference segments (R 2 = 0.8670 vs. 0.7351, p = 0.047), while numerically higher for area (R 2 = 0.8663 vs. 0.7806, p = 0.157). Conclusions: In phantom model and human coronary arteries, IVUS vs. FD-OCTAbstract: Background: This purpose of this study is to evaluate, concomitantly with quantitative coronary angiography (QCA), the potential discrepancy between frequency domain optical coherence tomography (FD-OCT) and intravascular ultrasound (IVUS) measurements in a phantom coronary model and in human coronary arteries within and outside stented segments. Methods: FD-OCT and IVUS images sequentially obtained from a phantom coronary model and 57 stented human coronary arteries were compared between each other and with QCA. Results: Lumen area (LA) by IVUS was 10.1% larger (6.43 ± 0.09 mm 2 ) while by FD-OCT was similar (5.78 ± 0.09 mm 2 ) to actual phantom LA (5.72 mm 2 ); IVUS vs. FD-OCT stent area (SA) was 4.2% larger. In human coronary artery, diameter by QCA was smaller than by IVUS and OCT in reference (by 10.5% and 3.5%, both p < 0.001) and stented (3.6%, p < 0.001; and 1.7%, p = 0.012) segments. IVUS vs. FD-OCT distal reference LA was significantly larger (6.19 ± 2.18 mm 2 vs. 5.49 ± 2.49 mm 2, p < 0.001, respectively), and SA was numerically larger (7.42 ± 2.28 mm 2 vs. 7.22 ± 2.48 mm 2, p = 0.059) with larger discrepancy in reference (11.3%) than stented (2.7%) segments. IVUS vs. FD-OCT correlation for diameter was significantly higher for stented than reference segments (R 2 = 0.8670 vs. 0.7351, p = 0.047), while numerically higher for area (R 2 = 0.8663 vs. 0.7806, p = 0.157). Conclusions: In phantom model and human coronary arteries, IVUS vs. FD-OCT measurements were larger, particularly in non-stented than stented segments, and diameter was smaller by QCA vs. IVUS or FD-OCT. Despite undefined clinical significance, said discrepancy warrants consideration. … (more)
- Is Part Of:
- International journal of cardiology. Volume 221(2016)
- Journal:
- International journal of cardiology
- Issue:
- Volume 221(2016)
- Issue Display:
- Volume 221, Issue 2016 (2016)
- Year:
- 2016
- Volume:
- 221
- Issue:
- 2016
- Issue Sort Value:
- 2016-0221-2016-0000
- Page Start:
- 860
- Page End:
- 866
- Publication Date:
- 2016-10-15
- Subjects:
- Frequency domain optical coherence tomography -- Intravascular ultrasound -- Size discrepancy
Cardiology -- Periodicals
Electronic journals
616.12 - Journal URLs:
- http://www.clinicalkey.com/dura/browse/journalIssue/01675273 ↗
http://www.sciencedirect.com/science/journal/01675273 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijcard.2016.07.080 ↗
- Languages:
- English
- ISSNs:
- 0167-5273
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.158000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2719.xml