Calibration of polydimethylsiloxane and XAD-Pocket passive air samplers (PAS) for measuring gas- and particle-phase SVOCs. (October 2016)
- Record Type:
- Journal Article
- Title:
- Calibration of polydimethylsiloxane and XAD-Pocket passive air samplers (PAS) for measuring gas- and particle-phase SVOCs. (October 2016)
- Main Title:
- Calibration of polydimethylsiloxane and XAD-Pocket passive air samplers (PAS) for measuring gas- and particle-phase SVOCs
- Authors:
- Okeme, Joseph O.
Saini, Amandeep
Yang, Congqiao
Zhu, Jiping
Smedes, Foppe
Klánová, Jana
Diamond, Miriam L. - Abstract:
- Abstract: Polydimethylsiloxane (PDMS) has seen wide use as the stationary phase of gas chromatographic columns, a passive sampler in water, and recently as a personal exposure sampler, while styrene divinyl-benzene copolymer (XAD) has been used extensively as a passive air sampler outdoors and indoors. We have introduced PDMS and XAD-Pocket as new indoor passive air samplers (PASs). The XAD-Pocket was designed to maximize the surface area-to-volume ratio of XAD and to minimize obstruction of air flow by the sampler housing. Methods were developed to expedite the use of these PASs for measuring phthalates, novel brominated flame-retardants (NFRs) and polybrominated diphenyl ethers (PBDEs) indoors. Sampling rates, R s, (m 3 day −1 ), were measured during a 7-week calibration study. Variability within and between analyte groups was not statistically significant. As a result, generic values of 0.8 ± 0.4 and 0.5 ± 0.3 m 3 day −1 dm −2 are recommended for PDMS and XAD-Pocket for a 50-day deployment time, respectively. PDMS has a higher uptake rate and is easier to use than XAD-Pocket. Highlights: PDMS and XAD-Pocket presented as indoor passive air samplers. Both PASs calibrated for measuring phthalates, NFRs and PBDEs indoors. R s of 0.8 ± 0.4 and 0.5 ± 0.3 m 3 day −1 dm −2 for PDMS and XAD-Pocket, respectively. PDMS has a higher uptake rate and greater ease of use than XAD-Pocket.
- Is Part Of:
- Atmospheric environment. Volume 143(2016)
- Journal:
- Atmospheric environment
- Issue:
- Volume 143(2016)
- Issue Display:
- Volume 143, Issue 2016 (2016)
- Year:
- 2016
- Volume:
- 143
- Issue:
- 2016
- Issue Sort Value:
- 2016-0143-2016-0000
- Page Start:
- 202
- Page End:
- 208
- Publication Date:
- 2016-10
- Subjects:
- Passive sampling -- Calibration -- PDMS -- XAD-Pocket -- Phthalates -- Flame-retardants
Air -- Pollution -- Periodicals
Air -- Pollution -- Meteorological aspects -- Periodicals
551.51 - Journal URLs:
- http://www.sciencedirect.com/web-editions/journal/13522310 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.atmosenv.2016.08.023 ↗
- Languages:
- English
- ISSNs:
- 1352-2310
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1767.120000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2203.xml