Calibration and application of ductile fracture criterion under non-proportional loading condition. (October 2016)
- Record Type:
- Journal Article
- Title:
- Calibration and application of ductile fracture criterion under non-proportional loading condition. (October 2016)
- Main Title:
- Calibration and application of ductile fracture criterion under non-proportional loading condition
- Authors:
- Zhuang, Xincun
Wang, Tingting
Zhu, Xianfeng
Zhao, Zhen - Abstract:
- Abstract: Two series of experiments were designed and carried out to evaluate the performance of the selected ductile fracture criterion, of which one is the experiments under monotonic loading conditions and the other is the experiments under non-proportional loading conditions. Combined with parallel numerical simulations, the experiments under monotonic loading conditions were utilized to identify the parameters of the fracture criterion with two calibration methods, a conditional one applying several experiments to calculate material constants and an optimization one of surface fitting. The prediction accuracy of fracture related state variables by using the ductile fracture criterion with different calibration methods in regard of the experimental results were estimated. It could be seen that the calibrated L-H fracture criterion via both calibration methods could be qualified for the evaluation of damage evolution in the experiments under monotonic loading conditions. The addition of pre-torsion on the tension test could shift the fracture initiation point from the center to the outside edge. While for the cases under compression-torsion loading conditions, the situation is not consistent due to the cut-off value of stress traxiality used in L-H fracture criterion. With the increase of the pre-loading amount, the prediction accuracy of the identified fracture criterion deteriorates, which is probably caused by the adoption of invariant model parameters or the error ofAbstract: Two series of experiments were designed and carried out to evaluate the performance of the selected ductile fracture criterion, of which one is the experiments under monotonic loading conditions and the other is the experiments under non-proportional loading conditions. Combined with parallel numerical simulations, the experiments under monotonic loading conditions were utilized to identify the parameters of the fracture criterion with two calibration methods, a conditional one applying several experiments to calculate material constants and an optimization one of surface fitting. The prediction accuracy of fracture related state variables by using the ductile fracture criterion with different calibration methods in regard of the experimental results were estimated. It could be seen that the calibrated L-H fracture criterion via both calibration methods could be qualified for the evaluation of damage evolution in the experiments under monotonic loading conditions. The addition of pre-torsion on the tension test could shift the fracture initiation point from the center to the outside edge. While for the cases under compression-torsion loading conditions, the situation is not consistent due to the cut-off value of stress traxiality used in L-H fracture criterion. With the increase of the pre-loading amount, the prediction accuracy of the identified fracture criterion deteriorates, which is probably caused by the adoption of invariant model parameters or the error of numerical simulation of strain hardening response based on the assumption of isotropic hardening. … (more)
- Is Part Of:
- Engineering fracture mechanics. Volume 165(2016)
- Journal:
- Engineering fracture mechanics
- Issue:
- Volume 165(2016)
- Issue Display:
- Volume 165, Issue 2016 (2016)
- Year:
- 2016
- Volume:
- 165
- Issue:
- 2016
- Issue Sort Value:
- 2016-0165-2016-0000
- Page Start:
- 39
- Page End:
- 56
- Publication Date:
- 2016-10
- Subjects:
- Monotonic loading -- Non-proportional loading -- Ductile fracture -- Stress triaxiality -- Lode parameter
Fracture mechanics -- Periodicals
Rupture, Mécanique de la -- Périodiques
Fracture mechanics
Periodicals
620.112605 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00137944 ↗
http://www.elsevier.com/journals ↗
http://www.elsevier.com/wps/find/homepage.cws_home ↗ - DOI:
- 10.1016/j.engfracmech.2016.08.021 ↗
- Languages:
- English
- ISSNs:
- 0013-7944
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3761.350000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1181.xml