Safety and feasibility of the RhinoChill immediate transnasal evaporative cooling device during out-of-hospital cardiopulmonary resuscitation: A single-center, observational study. Issue 34 (August 2016)
- Record Type:
- Journal Article
- Title:
- Safety and feasibility of the RhinoChill immediate transnasal evaporative cooling device during out-of-hospital cardiopulmonary resuscitation: A single-center, observational study. Issue 34 (August 2016)
- Main Title:
- Safety and feasibility of the RhinoChill immediate transnasal evaporative cooling device during out-of-hospital cardiopulmonary resuscitation
- Authors:
- Grave, Marie-Sophie
Sterz, Fritz
Nürnberger, Alexander
Fykatas, Stergios
Gatterbauer, Mathias
Stättermayer, Albert Friedrich
Zajicek, Andreas
Malzer, Reinhard
Sebald, Dieter
van Tulder, Raphael - Other Names:
- Adesina. Adebowale section editor.
- Abstract:
- Abstract : Abstract: We investigated feasibility and safety of the RhinoChill (RC) transnasal cooling system initiated before achieving a protected airway during cardiopulmonary resuscitation (CPR) in a prehospital setting. In out-of-hospital cardiac arrest (OHCA), transnasal evaporative cooling was initiated during CPR, before a protected airway was established and continued until either the patient was declared dead, standard institutional systemic cooling methods were implemented or cooling supply was empty. Patients were monitored throughout the hypothermia period until either death or hospital discharge. Clinical assessments and relevant adverse events (AEs) were documented over this period of time. In total 21 patients were included. Four were excluded due to user errors or meeting exclusion criteria. Finally, 17 patients (f = 6; mean age 65.5 years, CI95%: 57.7–73.4) were analyzed. Device-related AEs, like epistaxis or nose whitening, occurred in 2 patients. They were mild and had no consequence on the patient's outcome. According to the field reports of the emergency medical services (EMS) personnel, no severe technical problems occurred by using the RC device that led to a delay or the impairment of quality of the CPR. Early application of the RC device, during OHCA is feasible, safe, easy to handle, and does not delay or hinder CPR, or establishment of a secure intubation. For efficacy and further safety data additional studies will be needed.
- Is Part Of:
- Medicine. Volume 95:Issue 34(2016)
- Journal:
- Medicine
- Issue:
- Volume 95:Issue 34(2016)
- Issue Display:
- Volume 95, Issue 34 (2016)
- Year:
- 2016
- Volume:
- 95
- Issue:
- 34
- Issue Sort Value:
- 2016-0095-0034-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-08
- Subjects:
- airway management -- cardiopulmonary resuscitation -- feasibility studies -- hypothermia -- induced -- nasopharynx -- safety
Medicine -- Periodicals
Medicine -- Periodicals
Médecine -- Périodiques
Geneeskunde
Medicine
Periodicals
Periodicals
610.5 - Journal URLs:
- http://journals.lww.com/md-journal/pages/default.aspx ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&PAGE=toc&D=ovft&MODE=ovid&NEWS=N&AN=00002060-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MD.0000000000004692 ↗
- Languages:
- English
- ISSNs:
- 0025-7974
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5534.000000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 947.xml