Are Accelerometers and GPS Devices Valid, Reliable and Feasible Tools for Measurement of Community Ambulation After Stroke?1. Issue 2 (8th June 2016)
- Record Type:
- Journal Article
- Title:
- Are Accelerometers and GPS Devices Valid, Reliable and Feasible Tools for Measurement of Community Ambulation After Stroke?1. Issue 2 (8th June 2016)
- Main Title:
- Are Accelerometers and GPS Devices Valid, Reliable and Feasible Tools for Measurement of Community Ambulation After Stroke?1
- Authors:
- Mahendran, Niruthikha
Kuys, Suzanne S.
Downie, Emma
Ng, Phoebe
Brauer, Sandra G. - Abstract:
- Abstract : Purpose: To determine validity, reliability and feasibility of accelerometers (ActivPAL ™, Sensewear Pro2 Armband) and portable global positioning systems (GPS) (Garmin Forerunner 405CX) for community ambulation measurement after stroke. Methods: Fifteen community-dwelling stroke survivors attended two sessions; completing a 6-minute walk, treadmill walking, and 200-m outdoor circuit. Feasibility was determined by wearing devices over four days. Measures collected included step count, time spent walking, distance, energy expenditure and location. Intra-class correlation coefficients (ICC), Bland–Altman plots and absolute percentage of error (APE) were used to determine validity and reliability. Results: ActivPAL ™ had excellent validity and reliability for most measures (ICC: 0.821–0.999, APE: 0%–11.1%), except for good-excellent findings at speeds < 0.42 m/s (ICC: 0.659–0.894, APE: 1.6%–11.1%). Sensewear had missing values for 23% of recordings and high error for all measures. GPS demonstrated excellent validity and reliability for time spent walking and step count (ICC: 0.805–0.999, APE: 0.9%–10%), and 100% accuracy for location. However, it was not valid or reliable for distance (ICC = −0.139, APE = 23.8%). All devices appeared feasible for community ambulation measurement with assistance for setup and data analysis. Conclusions: ActivPAL ™ and Garmin GPS appear valid, reliable and feasible tools for community ambulation measurement after stroke, except forAbstract : Purpose: To determine validity, reliability and feasibility of accelerometers (ActivPAL ™, Sensewear Pro2 Armband) and portable global positioning systems (GPS) (Garmin Forerunner 405CX) for community ambulation measurement after stroke. Methods: Fifteen community-dwelling stroke survivors attended two sessions; completing a 6-minute walk, treadmill walking, and 200-m outdoor circuit. Feasibility was determined by wearing devices over four days. Measures collected included step count, time spent walking, distance, energy expenditure and location. Intra-class correlation coefficients (ICC), Bland–Altman plots and absolute percentage of error (APE) were used to determine validity and reliability. Results: ActivPAL ™ had excellent validity and reliability for most measures (ICC: 0.821–0.999, APE: 0%–11.1%), except for good-excellent findings at speeds < 0.42 m/s (ICC: 0.659–0.894, APE: 1.6%–11.1%). Sensewear had missing values for 23% of recordings and high error for all measures. GPS demonstrated excellent validity and reliability for time spent walking and step count (ICC: 0.805–0.999, APE: 0.9%–10%), and 100% accuracy for location. However, it was not valid or reliable for distance (ICC = −0.139, APE = 23.8%). All devices appeared feasible for community ambulation measurement with assistance for setup and data analysis. Conclusions: ActivPAL ™ and Garmin GPS appear valid, reliable and feasible tools for community ambulation measurement after stroke, except for distance. Sensewear demonstrated poor validity and reliability when worn on the paretic arm. … (more)
- Is Part Of:
- Brain impairment. Volume 17:Issue 2(2016)
- Journal:
- Brain impairment
- Issue:
- Volume 17:Issue 2(2016)
- Issue Display:
- Volume 17, Issue 2 (2016)
- Year:
- 2016
- Volume:
- 17
- Issue:
- 2
- Issue Sort Value:
- 2016-0017-0002-0000
- Page Start:
- 151
- Page End:
- 161
- Publication Date:
- 2016-06-08
- Subjects:
- Stroke, -- community ambulation, -- walking, -- reliability and validity, -- accelerometer, -- GPS
Brain Diseases -- Congresses
Brain Diseases -- Periodicals
Brain -- Diseases -- Periodicals
616.805 - Journal URLs:
- http://ejournals.ebsco.com/direct.asp?JournalID=112070 ↗
http://journals.cambridge.org/action/displayJournal?jid=BIM ↗ - DOI:
- 10.1017/BrImp.2016.13 ↗
- Languages:
- English
- ISSNs:
- 1443-9646
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 1188.xml