Two solvent/detergent‐treated plasma products with a different biochemical profile. (23rd June 2016)
- Record Type:
- Journal Article
- Title:
- Two solvent/detergent‐treated plasma products with a different biochemical profile. (23rd June 2016)
- Main Title:
- Two solvent/detergent‐treated plasma products with a different biochemical profile
- Authors:
- Neisser‐Svae, A.
Heger, A. - Abstract:
- Abstract : Background and Objectives: The distribution of US‐produced solvent/detergent (S/D)‐treated plasma (Plas+SD) was discontinued in 2003 due to bleeding and thrombotic events. In this work, we were searching for explanations that might explain these severe side‐effects. Materials and Methods: The activities of coagulation factors and inhibitors and von Willebrand factor (VWF) multimers were tested in three Plas+SD batches and compared with an S/D‐treated plasma named OctaplasLG. In addition, the Plas+SD process was investigated in downscale studies. Results: When compared to OctaplasLG, coagulation factors (F)V and FXI were significantly increased in the Plas+SD product, whereas FIX, protein C (PC), protein S (PS) and plasmin inhibitor (PI) were significantly decreased, leading to a haemostatic imbalance in this product. In addition, loss of high molecular weight VWF multimers was observed in the Plas+SD product compared to both OctaplasLG and normal plasma. Downscale studies of the Plas+SD manufacturing steps revealed significant losses of all parameters tested during the S/D‐treatment and removal steps. Except for PS and PI, which remained decreased by 47% and 65%, respectively, these losses were nearly compensated for the other parameters by the subsequent ultrafiltration step performed. Conclusion: Although both S/D plasma manufacturing processes have the same basic set‐up, differences in single process steps are responsible for the different biochemical profiles.Abstract : Background and Objectives: The distribution of US‐produced solvent/detergent (S/D)‐treated plasma (Plas+SD) was discontinued in 2003 due to bleeding and thrombotic events. In this work, we were searching for explanations that might explain these severe side‐effects. Materials and Methods: The activities of coagulation factors and inhibitors and von Willebrand factor (VWF) multimers were tested in three Plas+SD batches and compared with an S/D‐treated plasma named OctaplasLG. In addition, the Plas+SD process was investigated in downscale studies. Results: When compared to OctaplasLG, coagulation factors (F)V and FXI were significantly increased in the Plas+SD product, whereas FIX, protein C (PC), protein S (PS) and plasmin inhibitor (PI) were significantly decreased, leading to a haemostatic imbalance in this product. In addition, loss of high molecular weight VWF multimers was observed in the Plas+SD product compared to both OctaplasLG and normal plasma. Downscale studies of the Plas+SD manufacturing steps revealed significant losses of all parameters tested during the S/D‐treatment and removal steps. Except for PS and PI, which remained decreased by 47% and 65%, respectively, these losses were nearly compensated for the other parameters by the subsequent ultrafiltration step performed. Conclusion: Although both S/D plasma manufacturing processes have the same basic set‐up, differences in single process steps are responsible for the different biochemical profiles. The study performed may contribute to a better understanding of the side‐effects that occurred with the Plas+SD product. … (more)
- Is Part Of:
- ISBT science series. Volume 11:Number 2(2016)
- Journal:
- ISBT science series
- Issue:
- Volume 11:Number 2(2016)
- Issue Display:
- Volume 11, Issue 2 (2016)
- Year:
- 2016
- Volume:
- 11
- Issue:
- 2
- Issue Sort Value:
- 2016-0011-0002-0000
- Page Start:
- 94
- Page End:
- 101
- Publication Date:
- 2016-06-23
- Subjects:
- biochemical profile -- manufacturing process -- plasma transfusion -- S/D plasma
Blood -- Periodicals
Blood -- Transfusion -- Periodicals
Immunohematology -- Periodicals
Immunopathology -- Periodicals
615.39 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1751-2824 ↗
http://www.blackwell-synergy.com/loi/voxs ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/voxs.12282 ↗
- Languages:
- English
- ISSNs:
- 1751-2816
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4582.773100
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 884.xml