Ultra-trace metallic element detection in liquid samples using laser induced breakdown spectroscopy based on matrix conversion and crosslinked PVA polymer membrane. Issue 8 (15th June 2016)
- Record Type:
- Journal Article
- Title:
- Ultra-trace metallic element detection in liquid samples using laser induced breakdown spectroscopy based on matrix conversion and crosslinked PVA polymer membrane. Issue 8 (15th June 2016)
- Main Title:
- Ultra-trace metallic element detection in liquid samples using laser induced breakdown spectroscopy based on matrix conversion and crosslinked PVA polymer membrane
- Authors:
- Lin, Qingyu
Han, Xiaodan
Wang, Jie
Wei, Zhimei
Liu, Kunping
Duan, Yixiang - Abstract:
- Abstract : A novel, sensitive method based on crosslinked polyvinyl alcohol (PVA) was developed for determining trace-amounts of metallic elements in liquid samples using laser induced breakdown spectroscopy (LIBS). Abstract : A novel method with high sensitivity was developed for determining ultra-trace-amounts of metallic elements in liquids by LIBS analysis, based on crosslinked polyvinyl alcohol (PVA) supporting material. In this newly proposed approach, an aqueous solution sample was intensively mixed with PVA solution leading to phase conversion, which is distinguished from the desiccation process on a solid supporter as reported in the literature of liquid-to-solid conversion for LIBS analysis. The analytes were distributed in a thin PVA film (0.34 mm) as a result of crosslinking the polymer materials, and thereby the plasma signals generated by laser pulse were stronger and a lower amount of solid supporter was needed compared to traditional methods. Due to the low PVA thermal decomposition temperature, laser generated plasma energy was effectively utilized for not only ablating the sample, but rather exciting analytes within the sample. The limits of detection for Ag, Cu, Cr, Pb, Ni, Co and Cd obtained in this study were 1 ng mL −1, 8 ng mL −1, 16 ng mL −1, 1 μg mL −1, 1 μg mL −1, 2 μg mL −1 and 5 μg mL −1, respectively, which showed great improvement compared with those from direct liquid analysis by LIBS. The satisfactory figures of merits of the proposed method,Abstract : A novel, sensitive method based on crosslinked polyvinyl alcohol (PVA) was developed for determining trace-amounts of metallic elements in liquid samples using laser induced breakdown spectroscopy (LIBS). Abstract : A novel method with high sensitivity was developed for determining ultra-trace-amounts of metallic elements in liquids by LIBS analysis, based on crosslinked polyvinyl alcohol (PVA) supporting material. In this newly proposed approach, an aqueous solution sample was intensively mixed with PVA solution leading to phase conversion, which is distinguished from the desiccation process on a solid supporter as reported in the literature of liquid-to-solid conversion for LIBS analysis. The analytes were distributed in a thin PVA film (0.34 mm) as a result of crosslinking the polymer materials, and thereby the plasma signals generated by laser pulse were stronger and a lower amount of solid supporter was needed compared to traditional methods. Due to the low PVA thermal decomposition temperature, laser generated plasma energy was effectively utilized for not only ablating the sample, but rather exciting analytes within the sample. The limits of detection for Ag, Cu, Cr, Pb, Ni, Co and Cd obtained in this study were 1 ng mL −1, 8 ng mL −1, 16 ng mL −1, 1 μg mL −1, 1 μg mL −1, 2 μg mL −1 and 5 μg mL −1, respectively, which showed great improvement compared with those from direct liquid analysis by LIBS. The satisfactory figures of merits of the proposed method, including linearity, reproducibility and accuracy, were also obtained with the optimal experimental parameters. This unique method takes advantage of mixing an aqueous solution sample with supporter material in a liquid phase and it has characteristics of fast, simple and sensitive analysis for liquid sample compared with conventional liquid-to-solid conversion methods for LIBS. … (more)
- Is Part Of:
- Journal of analytical atomic spectrometry. Volume 31:Issue 8(2016:Aug.)
- Journal:
- Journal of analytical atomic spectrometry
- Issue:
- Volume 31:Issue 8(2016:Aug.)
- Issue Display:
- Volume 31, Issue 8 (2016)
- Year:
- 2016
- Volume:
- 31
- Issue:
- 8
- Issue Sort Value:
- 2016-0031-0008-0000
- Page Start:
- 1622
- Page End:
- 1630
- Publication Date:
- 2016-06-15
- Subjects:
- Atomic spectra -- Periodicals
Atomic absorption spectroscopy -- Periodicals
543.0858 - Journal URLs:
- http://pubs.rsc.org/en/journals/journalissues/ja#!recentarticles&adv ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c6ja00177g ↗
- Languages:
- English
- ISSNs:
- 0267-9477
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4928.200000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 647.xml