Clinical factors affecting the accuracy of a CT‐based active infrared navigation system. Issue 3 (31st July 2015)
- Record Type:
- Journal Article
- Title:
- Clinical factors affecting the accuracy of a CT‐based active infrared navigation system. Issue 3 (31st July 2015)
- Main Title:
- Clinical factors affecting the accuracy of a CT‐based active infrared navigation system
- Authors:
- Liu, Yajun
Zhao, Jingwei
Fan, Mingxing
Lv, Yanwei
Liu, Wenyong
Tian, Wei - Abstract:
- Abstract: Background: Computer‐assisted navigation technology has been widely used during spine surgery; however, the desired accuracy cannot be easily obtained and sustained. Our goal was to determine whether and how clinical factors affect the accuracy of a CT‐based active infrared navigation system. Methods: Using the Sawbone model, we recorded the clinical accuracy of the navigation system, based on several clinical statuses. Results: Clinical accuracy may change when the height or angle of the bed is changed. Within the visible area of the camera, the nearer the distance between the camera and the model, the better the clinical accuracy. The clinical accuracy of the CT‐based active infrared navigation system may decrease due to exposure to shadowless lamps. Conclusions: The clinical accuracy of the CT‐based active infrared navigation system may be influenced by the clinical status of shadowless lamps, different distances between the camera and model and different postures of the surgical bed. Copyright © 2015 John Wiley & Sons, Ltd.
- Is Part Of:
- International journal of medical robotics and computer assisted surgery. Volume 12:Issue 3(2016)
- Journal:
- International journal of medical robotics and computer assisted surgery
- Issue:
- Volume 12:Issue 3(2016)
- Issue Display:
- Volume 12, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 12
- Issue:
- 3
- Issue Sort Value:
- 2016-0012-0003-0000
- Page Start:
- 568
- Page End:
- 571
- Publication Date:
- 2015-07-31
- Subjects:
- computer‐assisted orthopaedic surgery (CAOS) -- spine -- navigation -- clinical accuracy
Robotics in medicine -- Periodicals
Surgery -- Technological innovations -- Periodicals
Imaging systems in medicine -- Periodicals
617.90285 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1478-596X ↗
http://www.roboticpublications.com ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/rcs.1693 ↗
- Languages:
- English
- ISSNs:
- 1478-5951
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.347800
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2479.xml