Effects of HCl pretreatment, drying, and storage on the stable isotope ratios of soil and sediment samples. (9th June 2016)
- Record Type:
- Journal Article
- Title:
- Effects of HCl pretreatment, drying, and storage on the stable isotope ratios of soil and sediment samples. (9th June 2016)
- Main Title:
- Effects of HCl pretreatment, drying, and storage on the stable isotope ratios of soil and sediment samples
- Authors:
- Kim, Min‐Seob
Lee, Won‐Seok
Suresh Kumar, K.
Shin, Kyung‐Hoon
Robarge, Wayne
Kim, Minseok
Lee, Sang Ryong - Abstract:
- Abstract : Rationale: Stable isotope (δ 13 C, δ 15 N, δ 34 S values) analysis has become increasingly important for tracing contaminant sources in environments. Pretreatment of environmental samples allows accurate analysis of stable isotope ratios. The pretreatment of a sample and its subsequent preservation could either contaminate or create experimental artifacts affecting the validity of the resulting C/N ratios and the elemental isotopic contents of a sample. Methods: The effects of acid pretreatment (0.1, 0.5, 1, 2, 5, 13 M HCl) and exposure period (2, 6, 12, 24, and 48 h) on the stable isotopic ratios of marine sediment (MS), river sediment (RS) and terrestrial soil (TS) samples were evaluated. The effects of storage temperatures (–80, –20 and 2°C), storage duration (1 week, 1 to 12 months) and washing steps (1, 2, 3, 5, 7 or 12 times) on the stable isotopic ratios were also considered. The %C, %N and %S, as well as the δ 13 C, δ 15 N, and δ 34 S values, of each sample were measured using continuous flow Elemental Analyzer/Isotope Ratio Mass Spectrometry (EA/IRMS). Results: The HCl treatment was applicable for δ 13 C analysis. However, the acid concentration and duration of exposure that brought about total removal of carbonate for the three sample types varied; e.g. the TS sample required stronger acid and a shorter exposure time. Storage time also had an effect: the δ 13 C values were lower and the δ 15 N and δ 34 S values higher after storage for 300 days.Abstract : Rationale: Stable isotope (δ 13 C, δ 15 N, δ 34 S values) analysis has become increasingly important for tracing contaminant sources in environments. Pretreatment of environmental samples allows accurate analysis of stable isotope ratios. The pretreatment of a sample and its subsequent preservation could either contaminate or create experimental artifacts affecting the validity of the resulting C/N ratios and the elemental isotopic contents of a sample. Methods: The effects of acid pretreatment (0.1, 0.5, 1, 2, 5, 13 M HCl) and exposure period (2, 6, 12, 24, and 48 h) on the stable isotopic ratios of marine sediment (MS), river sediment (RS) and terrestrial soil (TS) samples were evaluated. The effects of storage temperatures (–80, –20 and 2°C), storage duration (1 week, 1 to 12 months) and washing steps (1, 2, 3, 5, 7 or 12 times) on the stable isotopic ratios were also considered. The %C, %N and %S, as well as the δ 13 C, δ 15 N, and δ 34 S values, of each sample were measured using continuous flow Elemental Analyzer/Isotope Ratio Mass Spectrometry (EA/IRMS). Results: The HCl treatment was applicable for δ 13 C analysis. However, the acid concentration and duration of exposure that brought about total removal of carbonate for the three sample types varied; e.g. the TS sample required stronger acid and a shorter exposure time. Storage time also had an effect: the δ 13 C values were lower and the δ 15 N and δ 34 S values higher after storage for 300 days. Conclusions: HCl pretreatment effectively eliminates carbonates and thereby helps δ 13 C analysis of the organic fraction. HCl pretreatment is not recommended for δ 15 N and δ 34 S analysis. Freeze‐drying of samples is recommended rather than oven drying. A temperature‐dependent change in the isotopic ratios of long‐term stored samples was observed during this study; therefore, relatively short‐term storage (–80°C) of freeze‐dried samples is preferable. Copyright © 2016 John Wiley & Sons, Ltd. … (more)
- Is Part Of:
- Rapid communications in mass spectrometry. Volume 30:Number 13(2016)
- Journal:
- Rapid communications in mass spectrometry
- Issue:
- Volume 30:Number 13(2016)
- Issue Display:
- Volume 30, Issue 13 (2016)
- Year:
- 2016
- Volume:
- 30
- Issue:
- 13
- Issue Sort Value:
- 2016-0030-0013-0000
- Page Start:
- 1567
- Page End:
- 1575
- Publication Date:
- 2016-06-09
- Subjects:
- Mass spectrometry -- Periodicals
543.65 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/rcm.7600 ↗
- Languages:
- English
- ISSNs:
- 0951-4198
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7254.440000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 78.xml