Incidence of Significant Delayed Esophageal Temperature Drop After Cryoballoon‐Based Pulmonary Vein Isolation. (7th June 2016)
- Record Type:
- Journal Article
- Title:
- Incidence of Significant Delayed Esophageal Temperature Drop After Cryoballoon‐Based Pulmonary Vein Isolation. (7th June 2016)
- Main Title:
- Incidence of Significant Delayed Esophageal Temperature Drop After Cryoballoon‐Based Pulmonary Vein Isolation
- Authors:
- DEISS, SEBASTIAN
METZNER, ANDREAS
OUYANG, FEIFAN
TILZ, ROLAND R.
MATHEW, SHIBU
LEMES, CHRISTINE
HEEGER, CHRISTIAN‐H.
MAURER, TILMAN
KUCK, KARL‐HEINZ
WISSNER, ERIK - Abstract:
- Significant Delayed ET Drop After CB‐Based PV Vein Isolation: Background: The second‐generation cryoballoon (CB2) has demonstrated superior clinical outcome. Potential procedural complications include esophageal thermal lesions due to excessive esophageal temperature (ET). Safety cut‐offs for the ET have previously been published. A safety margin was incorporated due to a delayed esophageal temperature decline even after termination of the CB2 freeze cycle. The extent of these delayed temperature drops requires further systematic evaluation. Methods and Results: The study enrolled 29 patients with paroxysmal or shortstanding persistent AF who underwent CB2‐based PVI. Freeze cycle duration was 240 seconds. No bonus freeze was applied after successful PVI. The intraluminal ET was continuously measured via a transorally inserted probe (SensiTherm, St. Jude Medical, Inc.). The CB2 temperature and ET were recorded throughout the procedure using a camera setup. The mean number of freeze cycles per patient was 4.3 ± 2. A total of 147 cryoenergy applications were analyzed. A delayed decline in ET of >0.5 °C was recorded following termination of 23.1% of freeze cycles. The maximum drop in delayed ET was 6.4 °C. Excessive esophageal cooling during the freeze cycle exceeding 8.5 °C/min may result in ET ≤10 °C. Conclusions: Following termination of cryoenergy delivery, the ET may decline an additional 6.4 °C. Proposed ET safety cut‐offs during CB2‐based PVI need to account for aSignificant Delayed ET Drop After CB‐Based PV Vein Isolation: Background: The second‐generation cryoballoon (CB2) has demonstrated superior clinical outcome. Potential procedural complications include esophageal thermal lesions due to excessive esophageal temperature (ET). Safety cut‐offs for the ET have previously been published. A safety margin was incorporated due to a delayed esophageal temperature decline even after termination of the CB2 freeze cycle. The extent of these delayed temperature drops requires further systematic evaluation. Methods and Results: The study enrolled 29 patients with paroxysmal or shortstanding persistent AF who underwent CB2‐based PVI. Freeze cycle duration was 240 seconds. No bonus freeze was applied after successful PVI. The intraluminal ET was continuously measured via a transorally inserted probe (SensiTherm, St. Jude Medical, Inc.). The CB2 temperature and ET were recorded throughout the procedure using a camera setup. The mean number of freeze cycles per patient was 4.3 ± 2. A total of 147 cryoenergy applications were analyzed. A delayed decline in ET of >0.5 °C was recorded following termination of 23.1% of freeze cycles. The maximum drop in delayed ET was 6.4 °C. Excessive esophageal cooling during the freeze cycle exceeding 8.5 °C/min may result in ET ≤10 °C. Conclusions: Following termination of cryoenergy delivery, the ET may decline an additional 6.4 °C. Proposed ET safety cut‐offs during CB2‐based PVI need to account for a significant ET drop that may occur even after termination of the individual freeze cycle. … (more)
- Is Part Of:
- Journal of cardiovascular electrophysiology. Volume 27:Number 8(2016)
- Journal:
- Journal of cardiovascular electrophysiology
- Issue:
- Volume 27:Number 8(2016)
- Issue Display:
- Volume 27, Issue 8 (2016)
- Year:
- 2016
- Volume:
- 27
- Issue:
- 8
- Issue Sort Value:
- 2016-0027-0008-0000
- Page Start:
- 913
- Page End:
- 917
- Publication Date:
- 2016-06-07
- Subjects:
- atrial fibrillation -- catheter ablation -- cryoballoon -- thermal lesions
Blood vessels -- Physiology -- Periodicals
Electrophysiology -- Periodicals
Heart -- Physiology -- Periodicals
612.1 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/jce.13008 ↗
- Languages:
- English
- ISSNs:
- 1045-3873
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.866000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 2349.xml