New genotyping method discovers sustained nosocomial Pseudomonas aeruginosa outbreak in an intensive care burn unit. Issue 1 (September 2016)
- Record Type:
- Journal Article
- Title:
- New genotyping method discovers sustained nosocomial Pseudomonas aeruginosa outbreak in an intensive care burn unit. Issue 1 (September 2016)
- Main Title:
- New genotyping method discovers sustained nosocomial Pseudomonas aeruginosa outbreak in an intensive care burn unit
- Authors:
- Tissot, F.
Blanc, D.S.
Basset, P.
Zanetti, G.
Berger, M.M.
Que, Y.-A.
Eggimann, P.
Senn, L. - Abstract:
- Summary: Background: Pseudomonas aeruginosa is a leading cause of healthcare-associated infections in the intensive care unit (ICU). Aim: To investigate an unexplained increase in the incidence of P. aeruginosa recovered from clinical samples in the ICU over a two-year period. Methods: After unsuccessful epidemiological investigation by conventional tools, P. aeruginosa clinical isolates of all patients hospitalized between January 2010 and July 2012 were typed by a novel double-locus sequence typing (DLST) method and compared to environmental isolates recovered during the investigation period. Findings: In total, 509 clinical isolates from 218 patients and 91 environmental isolates were typed. Thirty-five different genotypic clusters were found in 154 out of 218 patients (71%). The largest cluster, DLST 1-18, included 23 patients who were mostly hospitalized during overlapping periods in the burn unit. Genotype DLST 1-18 was also recovered from floor traps, shower trolleys and the shower mattress in the hydrotherapy rooms, suggesting environmental contamination of the burn unit as the source of the outbreak. After implementation of appropriate infection control measures, this genotype was recovered only once in a clinical sample from a burned patient and twice in the environment, but never thereafter during a 12-month follow-up period. Conclusion: The use of a novel DLST method allowed the genotyping of a large number of clinical and environmental isolates, leading to theSummary: Background: Pseudomonas aeruginosa is a leading cause of healthcare-associated infections in the intensive care unit (ICU). Aim: To investigate an unexplained increase in the incidence of P. aeruginosa recovered from clinical samples in the ICU over a two-year period. Methods: After unsuccessful epidemiological investigation by conventional tools, P. aeruginosa clinical isolates of all patients hospitalized between January 2010 and July 2012 were typed by a novel double-locus sequence typing (DLST) method and compared to environmental isolates recovered during the investigation period. Findings: In total, 509 clinical isolates from 218 patients and 91 environmental isolates were typed. Thirty-five different genotypic clusters were found in 154 out of 218 patients (71%). The largest cluster, DLST 1-18, included 23 patients who were mostly hospitalized during overlapping periods in the burn unit. Genotype DLST 1-18 was also recovered from floor traps, shower trolleys and the shower mattress in the hydrotherapy rooms, suggesting environmental contamination of the burn unit as the source of the outbreak. After implementation of appropriate infection control measures, this genotype was recovered only once in a clinical sample from a burned patient and twice in the environment, but never thereafter during a 12-month follow-up period. Conclusion: The use of a novel DLST method allowed the genotyping of a large number of clinical and environmental isolates, leading to the identification of the environmental source of a large unrecognized outbreak in the burn unit. Eradication of the outbreak was confirmed after implementation of a continuous epidemiological surveillance of P. aeruginosa clones in the ICU. … (more)
- Is Part Of:
- Journal of hospital infection. Volume 94:Issue 1(2016)
- Journal:
- Journal of hospital infection
- Issue:
- Volume 94:Issue 1(2016)
- Issue Display:
- Volume 94, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 94
- Issue:
- 1
- Issue Sort Value:
- 2016-0094-0001-0000
- Page Start:
- 2
- Page End:
- 7
- Publication Date:
- 2016-09
- Subjects:
- Pseudomonas aeruginosa -- Intensive care unit -- Burns -- Outbreak -- Molecular typing
Cross infection -- Periodicals
Cross infection -- Prevention -- Periodicals
Nosocomial infections -- Periodicals
Nosocomial infections -- Prevention -- Periodicals
Cross Infection -- Periodicals
Cross Infection -- prevention & control -- Periodicals
Infection Control -- Periodicals
Electronic journals
614.44 - Journal URLs:
- http://www.harcourt-international.com/journals ↗
http://www.clinicalkey.com/dura/browse/journalIssue/01956701 ↗
http://www.sciencedirect.com/science/journal/01956701 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jhin.2016.05.011 ↗
- Languages:
- English
- ISSNs:
- 0195-6701
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5003.285000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2656.xml